Evidence map›Paper›PMID 39137171›Full record

ArticlePLOS digital health2024

QRS detection in single-lead, telehealth electrocardiogram signals: Benchmarking open-source algorithms.

Florian Kristof, Maximilian Kapsecker, Leon Nissen, James Brimicombe, Martin R Cowie, Zixuan Ding, Andrew Dymond, Stephan M Jonas, Hannah Clair Lindén, Gregory Y H Lip and 4 more

Abstract read
In one paragraph

Article in PLOS digital health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Florian KristofTUM School of Computation, Information, and Technology, Technical University of Munich, Garching bei München, Germany.
Maximilian KapseckerTUM School of Computation, Information, and Technology, Technical University of Munich, Garching bei München, Germany.
Leon NissenInstitute for Digital Medicine, University Hospital Bonn, Bonn, Germany.
James BrimicombeDepartment of Public Health and Primary Care, University of Cambridge, Cambridge, United Kingdom.
Martin R CowieSchool of Cardiovascular Medicine & Sciences, Faculty of Lifesciences & Medicine, King's College London, London, United Kingdom.
Zixuan DingDepartment of Public Health and Primary Care, University of Cambridge, Cambridge, United Kingdom.
Andrew DymondDepartment of Public Health and Primary Care, University of Cambridge, Cambridge, United Kingdom.
Stephan M JonasInstitute for Digital Medicine, University Hospital Bonn, Bonn, Germany.
Hannah Clair LindénZenicor Medical Systems AB, Stockholm, Sweden.
Gregory Y H LipLiverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, United Kingdom.
Kate WilliamsDepartment of Public Health and Primary Care, University of Cambridge, Cambridge, United Kingdom.ORCID https://orcid.org/0000-0002-6188-9363
Jonathan MantDepartment of Public Health and Primary Care, University of Cambridge, Cambridge, United Kingdom.
Peter H CharltonDepartment of Public Health and Primary Care, University of Cambridge, Cambridge, United Kingdom.ORCID https://orcid.org/0000-0003-3836-8655
SAFER Investigators

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectivesA key step in electrocardiogram (ECG) analysis is the detection of QRS complexes, particularly for arrhythmia detection. Telehealth ECGs present a new challenge for automated analysis as they are noisier than traditional clinical ECGs. The aim of this study was to identify the best-performing open-source QRS detector for use with telehealth ECGs.

methodsThe performance of 18 open-source QRS detectors was assessed on six datasets. These included four datasets of ECGs collected under supervision, and two datasets of telehealth ECGs collected without clinical supervision. The telehealth ECGs, consisting of single-lead ECGs recorded between the hands, included a novel dataset of 479 ECGs collected in the SAFER study of screening for atrial fibrillation (AF). Performance was assessed against manual annotations.

resultsA total of 12 QRS detectors performed well on ECGs collected under clinical supervision (F1 score ≥0.96). However, fewer performed well on telehealth ECGs: five performed well on the TELE ECG Database; six performed well on high-quality SAFER data; and performance was poorer on low-quality SAFER data (three QRS detectors achieved F1 of 0.78-0.84). The presence of AF had little impact on performance.

conclusionsThe Neurokit and University of New South Wales QRS detectors performed best in this study. These performed sufficiently well on high-quality telehealth ECGs, but not on low-quality ECGs. This demonstrates the need to handle low-quality ECGs appropriately to ensure only ECGs which can be accurately analysed are used for clinical decision making.

Identifiers

PMID39137171
PMCPMC7617317

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.