Evidence map›Paper›PMID 39136728›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2024

Risk factors for malalignment after intramedullary nail treatment of distal tibia fractures with associated fibula fractures.

Yash P Chaudhry, Jose M Gutierrez-Naranjo, Micheal Raad, Diane Ghanem, Luis M Salazar, Jason T Goodrum, Kitchai Luksameearunothai, Boris A Zelle, Erik A Hasenboehler

Abstract read
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Application of the distraction support in intramedullary nailing treatment for tibial shaft fracture.Chinese journal of traumatology = Zhonghua chuang shang za zhi · 2025
    Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yash P ChaudhryDepartment of Orthopaedic Surgery, Philadelphia College of Osteopathic Medicine, 4190 City Avenue, Philadelphia, PA, 19131, USA. yash.chaudhry.21@gmail.com.ORCID http://orcid.org/0000-0002-3721-1317
Jose M Gutierrez-NaranjoDepartment of Orthopaedics, UT Health San Antonio, San Antonio, TX, USA.
Micheal RaadDepartment of Orthopaedic Surgery, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Diane GhanemDepartment of Orthopaedic Surgery, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Luis M SalazarDepartment of Orthopaedics, UT Health San Antonio, San Antonio, TX, USA.
Jason T GoodrumDepartment of Orthopaedics, UT Health San Antonio, San Antonio, TX, USA.
Kitchai LuksameearunothaiFaculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand.
Boris A ZelleDepartment of Orthopaedics, UT Health San Antonio, San Antonio, TX, USA.
Erik A HasenboehlerHoly Spirit Medical Center Penn State Health, Orthopaedic Institute of Pennsylvania, Camp Hill, PA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeMalalignment of distal tibia fractures can lead to malunion/nonunion or alter the limb mechanical axis which may cause arthritis. Proposed methods to decrease malalignment include fibular fixation or multiplanar interlocking screws, however these remain controversial. This study aimed to identify factors associated with malalignment in distal tibial fractures with associated fibular shaft fractures.

methodsA retrospective review was performed of distal tibia fractures with associated fibular shaft fractures treated with intramedullary nailing at two level one trauma centers between 2015 and 2019. Cases involving malalignment (> 5° of deviation from anatomic axis on either coronal/sagittal axis) on final follow-up (minimum three months postoperatively) were compared to those without malalignment with regard to demographics, fracture characteristics, intraoperative characteristics, and complications.

resultsThe rate of malalignment was 13%. On multivariate analysis, multiplanar distal interlocking screw fixation (odds ratio [OR], 0.18; 95% confidence interval [CI] 0.03-0.92) was associated with a decreased rate of final malalignment, while nail diameter > 10 mm was associated with a higher rate (OR, 4.05; 95% CI 1.25-13.11). Fibular fixation was not associated with malalignment.

conclusionMultiplanar distal interlocking screws may protect against malalignment. Fibula fixation does not appear associated with a decreased rate of malalignment in distal tibia fractures treated with intramedullary nails. LEVEL OF EVIDENCE: III.

Indexed as

Bone MalalignmentFibulaFracture Fixation, IntramedullaryTibial FracturesAdultAgedBone NailsBone ScrewsFemaleFibula FracturesHumansMaleMiddle AgedPostoperative ComplicationsRetrospective StudiesRisk FactorsFibular fixationMalalignmentMultiplanar interlocking screw fixationTibial shaft fracture

Identifiers

PMID39136728
PMCPMC11377517

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked