Assessing the inter-observer and intra-observer reliability of radiographic measurements for size-specific dose estimates.

Faisal A Alrehily

Abstract read
In one paragraph

Article in BMC medical imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Faisal A AlrehilyDepartment of Diagnostic Radiology, College of Applied Medical Sciences (Building 115), Taibah University, Prince Naif Rd, Madinah, 42353, Saudi Arabia. frehily@taibahu.edu.sa.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCalculating size-specific dose estimates (SSDEs) requires measurement of the patient's anteroposterior (AP) and lateral thickness based on computed tomography (CT) images. However, these measurements can be subject to variation due to inter-observer and intra-observer differences. This study aimed to investigate the impact of these variations on the accuracy of the calculated SSDE.

methodsFour radiographers with 1-10 years of experience were invited to measure the AP and lateral thickness on 30 chest, abdomen, and pelvic CT images. The images were sourced from an internet-based database and anonymized for analysis. The observers were trained to perform the measurements using MicroDicom software and asked to repeat the measurements 1 week later. The study was approved by the institutional review board at Taibah University, and written informed consent was obtained from the observers. Statistical analyses were performed using Python libraries Pingouin (version 0.5.3), Seaborn (version 0.12.2), and Matplotlib (version 3.7.1).

resultsThe study revealed excellent inter-observer agreement for the calculated effective diameter and AP thickness measurements, with Intraclass correlation coefficients (ICC) values of 0.95 and 0.96, respectively. The agreement for lateral thickness measurements was lower, with an ICC value of 0.89. The second round of measurements yielded nearly the same levels of inter-observer agreement, with ICC values of 0.97 for the effective diameter, 1.0 for AP thickness, and 0.88 for lateral thickness. When the consistency of the observer was examined, excellent consistency was found for the calculated effective diameter, with ICC values ranging from 0.91 to 1.0 for all observers. This was observed despite the lower consistency in the lateral thickness measurements, which had ICC values ranging from 0.78 to 1.0.

conclusionsThe study's findings suggest that the measurements required for calculating SSDEs are robust to inter-observer and intra-observer differences. This is important for the clinical use of SSDEs to set diagnostic reference levels for CT scans.

Indexed as

Observer VariationRadiation DosageTomography, X-Ray ComputedFemaleHumansMaleMiddle AgedPelvisRadiography, AbdominalRadiography, ThoracicReproducibility of ResultsAgreementConsistencyCTDRLICCObserversReliabilitySSDE