Evidence map›Paper›PMID 39134937›Full record

ArticleBMC medical imaging2024

Dual-energy computed tomography with new virtual monoenergetic image reconstruction enhances prostate lesion image quality and improves the diagnostic efficacy for prostate cancer.

Nina Fan, Xiaofeng Chen, Yulin Li, Zhiqiang Zhu, Xiangguang Chen, Zhiqi Yang, Jiada Yang

Abstract read
In one paragraph

Article in BMC medical imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Nina Fan *Department of Radiology, Meizhou People's Hospital, Meizhou, 514000, Guangdong, China.
Xiaofeng Chen *Department of Radiology, Meizhou People's Hospital, Meizhou, 514000, Guangdong, China.
Yulin LiDepartment of Radiology, Meizhou People's Hospital, Meizhou, 514000, Guangdong, China.
Zhiqiang ZhuDepartment of Radiology, Meizhou People's Hospital, Meizhou, 514000, Guangdong, China.
Xiangguang ChenDepartment of Radiology, Meizhou People's Hospital, Meizhou, 514000, Guangdong, China.
Zhiqi YangDepartment of Radiology, Meizhou People's Hospital, Meizhou, 514000, Guangdong, China. y13643090854@163.com.
Jiada YangDepartment of Radiology, Meizhou People's Hospital, Meizhou, 514000, Guangdong, China. Catat1990@foxmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundProstate cancer is one of the most common malignant tumors in middle-aged and elderly men and carries significant prognostic implications, and recent studies suggest that dual-energy computed tomography (DECT) utilizing new virtual monoenergetic images can enhance cancer detection rates. This study aimed to assess the impact of virtual monoenergetic images reconstructed from DECT arterial phase scans on the image quality of prostate lesions and their diagnostic performance for prostate cancer.

methodsWe conducted a retrospective analysis of 83 patients with prostate cancer or prostatic hyperplasia who underwent DECT scans at Meizhou People's Hospital between July 2019 and December 2023. The variables analyzed included age, tumor diameter and serum prostate-specific antigen (PSA) levels, among others. We also compared CT values, signal-to-noise ratio (SNR), subjective image quality ratings, and contrast-to-noise ratio (CNR) between virtual monoenergetic images (40-100 keV) and conventional linear blending images. Receiver operating characteristic (ROC) curve analyses were performed to evaluate the diagnostic efficacy of virtual monoenergetic images (40 keV and 50 keV) compared to conventional images.

resultsVirtual monoenergetic images at 40 keV showed significantly higher CT values (168.19 ± 57.14) compared to conventional linear blending images (66.66 ± 15.5) for prostate cancer (P < 0.001). The 50 keV images also demonstrated elevated CT values (121.73 ± 39.21) compared to conventional images (P < 0.001). CNR values for the 40 keV (3.81 ± 2.13) and 50 keV (2.95 ± 1.50) groups were significantly higher than the conventional blending group (P < 0.001). Subjective evaluations indicated markedly better image quality scores for 40 keV (median score of 5) and 50 keV (median score of 5) images compared to conventional images (P < 0.05). ROC curve analysis revealed superior diagnostic accuracy for 40 keV (AUC: 0.910) and 50 keV (AUC: 0.910) images based on CT values compared to conventional images (AUC: 0.849).

conclusionsVirtual monoenergetic images reconstructed at 40 keV and 50 keV from DECT arterial phase scans substantially enhance the image quality of prostate lesions and improve diagnostic efficacy for prostate cancer.

Indexed as

Prostatic NeoplasmsSignal-To-Noise RatioTomography, X-Ray ComputedAgedAged, 80 and overHumansMaleMiddle AgedProstate-Specific AntigenProstatic HyperplasiaRadiographic Image Interpretation, Computer-AssistedRadiography, Dual-Energy Scanned ProjectionRetrospective StudiesROC CurveProstate-Specific AntigenDiagnostic performanceDual-energy computed tomographyProstate cancerVirtual monoenergetic images in arterial phase

Identifiers

PMID39134937
PMCPMC11321013

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.