ArticleScientific reports2024
Effect of liquid level monitor gas injection point size on information source amplitude-frequency characteristics.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
In order to analyse the effect of the injection point size of the CBM (Coalbed Methane) well level monitor on the amplitude and frequency of pressure pulsations in the wellhead manifold, numerical simulations and experiments were carried out to investigate the effect of different injection point sizes on the amplitude and frequency of pressure pulsations downstream of the sudden expansion structure. Using compressed air as the fluid and the size of the injection point as the variable, the amplitude and frequency of pressure pulsations at different locations downstream of the sudden expansion structure were tested. The results show that the pressure pulsation amplitude is affected by the size of the injection point, and the larger the injection point is, the larger the pressure pulsation amplitude is; the size of the injection point has less influence on the pressure pulsation frequency downstream of the protruding and expanding structure, and the pressure pulsation frequency at 0.5 m and 1 m downstream of the protruding and expanding structure is in the vicinity of 76 Hz. Therefore, the echo signal processing should be filtered around this frequency to obtain accurate liquid level echo signals, so as to improve the accuracy of liquid level monitoring and realise the efficient development of coalbed methane wells.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.