Evidence map›Paper›PMID 39134621›Full record

ArticleScientific reports2024

Effect of liquid level monitor gas injection point size on information source amplitude-frequency characteristics.

Pu Liu, Kailun Quan, Kaixuan Li, Xinyuan Wu, Zhongzhi Hu

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Pu LiuSichuan University of Science and Engineering, Zigong, China.
Kailun QuanSichuan University of Science and Engineering, Zigong, China. 507918398@qq.com.
Kaixuan LiShaanxi Stang Shenghe Oil & Gas Field Engineering & Technical Services Co., Yan'an, China.
Xinyuan WuSichuan University of Science and Engineering, Zigong, China.
Zhongzhi HuSichuan University of Science and Engineering, Zigong, China.

Funding

The Major Project of Yibin City on Key Technology Research for the Industrialization of Low-Cost and High-Energy-Density Battery Cathode Materials,The Energy-Saving and Environmental Protection Equipment Innovation Team,The Opening Project of Sichuan Province University Key Laboratory of Bridge Non-destruction Detecting and Engineering Computing 2023GY008The Major Project of Yibin City on Key Technology Research for the Industrialization of Low-Cost and High-Energy-Density Battery Cathode Materials,The Energy-Saving and Environmental Protection Equipment Innovation Team,The Opening Project of Sichuan Province University Key Laboratory of Bridge Non-destruction Detecting and Engineering Computing No. 2022QZJ02The Major Project of Yibin City on Key Technology Research for the Industrialization of Low-Cost and High-Energy-Density Battery Cathode Materials,The Energy-Saving and Environmental Protection Equipment Innovation Team,The Opening Project of Sichuan Province University Key Laboratory of Bridge Non-destruction Detecting and Engineering Computing No.SUSE652A010
6 · The paper itself

Abstract

In order to analyse the effect of the injection point size of the CBM (Coalbed Methane) well level monitor on the amplitude and frequency of pressure pulsations in the wellhead manifold, numerical simulations and experiments were carried out to investigate the effect of different injection point sizes on the amplitude and frequency of pressure pulsations downstream of the sudden expansion structure. Using compressed air as the fluid and the size of the injection point as the variable, the amplitude and frequency of pressure pulsations at different locations downstream of the sudden expansion structure were tested. The results show that the pressure pulsation amplitude is affected by the size of the injection point, and the larger the injection point is, the larger the pressure pulsation amplitude is; the size of the injection point has less influence on the pressure pulsation frequency downstream of the protruding and expanding structure, and the pressure pulsation frequency at 0.5 m and 1 m downstream of the protruding and expanding structure is in the vicinity of 76 Hz. Therefore, the echo signal processing should be filtered around this frequency to obtain accurate liquid level echo signals, so as to improve the accuracy of liquid level monitoring and realise the efficient development of coalbed methane wells.

Indexed as

Liquid level monitoringNumerical simulationPressure pulsationSudden expansion structure