Evidence map›Paper›PMID 39132558›Full record

ArticleJournal of the Society for Cardiovascular Angiography & Interventions

Safety and Efficacy of the Supreme Biodegradable Polymer Sirolimus-Eluting Stent in Patients With Diabetes Mellitus.

Alexander Thomas, Dean J Kereiakes, Andreas Baumbach, Stephan Windecker, Cody Pietras, Ovidiu Dressler, M Ozgu Issever, Michael Curtis, Barry Bertolet, James P Zidar and 11 more

Abstract read
In one paragraph

Article in Journal of the Society for Cardiovascular Angiography & Interventions. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

21 authors.

Alexander ThomasDivision of Cardiology, Yale School of Medicine, New Haven, Connecticut.
Dean J KereiakesChrist Hospital Heart and Vascular Center, Cincinnati, Ohio.
Andreas BaumbachDivision of Cardiology, Yale School of Medicine, New Haven, Connecticut.
Stephan WindeckerDepartment of Cardiology, Bern University Hospital, Inselspital, University of Bern, Switzerland.
Cody PietrasDivision of Cardiology, Yale School of Medicine, New Haven, Connecticut.
Ovidiu DresslerCardiovascular Research Foundation, New York, New York.
M Ozgu IsseverCardiovascular Research Foundation, New York, New York.
Michael CurtisUniversity of Calgary, Alberta, Canada.
Barry BertoletCardiology Associates of North Mississippi, Tupelo, Mississippi.
James P ZidarNorth Carolina Heart and Vascular, University of North Carolina, Raleigh, North Carolina.
Pieter C SmitsMaasstad Ziekenhuis, Rotterdam, the Netherlands.
Victor Alfonso Jiménez DíazHospital Álvaro Cunqueiro, Vigo, Spain.
Brent McLaurinAnMed Health Medical Center, Anderson, South Carolina.
Ángel CequierBellvitge Hospital, University of Barcelona, IDIBELL, Spain.
Akihiko TakahashiSakurakai Takahashi Hospital, Kobe, Japan.
Louis A CannonCardiac and Vascular Research Center of Northern Michigan, Petoskey, Michigan.
Giovanni AmorosoOnze Lieve Vrouwe Gasthuis, Amsterdam, the Netherlands.
Tsunekazu KakutaTsuchiura Kyodo Hospital, Tsuchiura, Japan.
Shigeru SaitoShonan Kamakura General Hospital, Kamakura, Japan.
Martin B LeonCardiovascular Research Foundation, New York, New York.
Alexandra J LanskyDivision of Cardiology, Yale School of Medicine, New Haven, Connecticut.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Patients with diabetes mellitus (DM) have worse outcomes following percutaneous coronary intervention than nondiabetic patients. The novel Supreme DES is a biodegradable polymer sirolimus-eluting stent designed to synchronize early drug delivery, limiting the potential for long-term inflammatory response. The purpose of this study was to evaluate the safety and efficacy of the Supreme DES in patients with DM. Methods: This is a prespecified analysis of the diabetic subgroup from the PIONEER III randomized (2:1), controlled trial, comparing the Supreme DES with a durable polymer everolimus-eluting stent (DP-EES). The primary safety and efficacy composite endpoint was target lesion failure at 1 year, a composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. Results: The PIONEER III trial randomized 1629 patients, of which 494 (30.3%) had DM with 331 (398 lesions) randomly assigned to Supreme DES and 163 (208 lesions) to DP-EES. Among patients with DM, target lesion failure at 1 year was 6.1% (20/331) with Supreme DES vs 3.7% (6/163) with DP-EES (hazard ratio = 1.65; 95% confidence interval = 0.66-4.10, Conclusions: This prespecified substudy of the PIONEER III trial demonstrated the relative safety and efficacy of the novel Supreme DES when compared with commercially available DP-EES in diabetics at 1 year. Longer term follow-up will be required to ensure continued safety and efficacy of the Supreme DES.

Indexed as

coronary revascularizationDiabetes mellitusdrug-eluting stentsoutcomes

Identifiers

PMID39132558
PMCPMC11307809

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.