ArticleJournal of the Society for Cardiovascular Angiography & Interventions
First-in-Human Experience With the ModulHeart Device for Mechanical Circulatory Support and Renal Perfusion.
Article in Journal of the Society for Cardiovascular Angiography & Interventions. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Device therapies in cardiorenal syndrome: an expert review.ESC heart failure · 2026Review
- Contemporary overview of current percutaneous mechanical circulatory support devices for advanced heart failure: a narrative review.Kardiochirurgia i torakochirurgia polska = Polish journal of cardio-thoracic surgery · 2026Review
- Hemodynamic performance and blood damage of the Intra-aortic pumps: A CFD-Based investigation.Medical & biological engineering & computing · 2026Article
- Device-based therapies in cardio-renal syndrome: a pathophysiology-driven approach to a complex bidirectional disease.Frontiers in cardiovascular medicine · 2026Review
- Decongestion in heart failure: medical and device therapies.Nature reviews. Cardiology · 2025Review
- A Novel Transaortic Pulsatile Pump to Unload the Left Ventricle.JACC. Basic to translational science · 2025Article
- Cardio-Renal Syndrome: Latest Developments in Device-Based Therapy.Journal of clinical medicine · 2024Review
- Preservation of von Willebrand Factor Activity With the ModulHeart Device.JACC. Basic to translational science · 2024Article
- Innovative Intra-Aortic Circulatory Support Pump: Novel Hemodynamics.Journal of the Society for Cardiovascular Angiography & InterventionsArticle
- Emerging Device Therapies for Cardiorenal Syndrome.Journal of the Society for Cardiovascular Angiography & InterventionsReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: ModulHeart (Puzzle Medical Devices Inc) is a modular device providing hemodynamic support through 3 endovascular pumps inserted in series and assembled in parallel into a self-expandable anchor implanted in the descending aorta. The current study evaluates the feasibility and safety of cardiorenal support with ModulHeart among patients undergoing high-risk percutaneous coronary intervention (PCI). Methods: This study was a prospective, single-center, first-in-human study. The primary end point was procedural success, defined as successful delivery, function, and removal of the ModulHeart device. Secondary end points included pump hemodynamics, cardiac hemodynamics, and urine output. Results: On June 28 and 29, 2022, 4 patients were enrolled and underwent high-risk PCI with ModulHeart implanted via transfemoral approach. All 4 patients achieved procedural success. The mean delivery time was 8 minutes, the mean support time was 49 minutes, and the mean pump removal time was 7 minutes. The mean pressure gradient across the pump was 5 ± 2 mm Hg. Under ModulHeart support, cardiac index increased by 25%, central venous pressure decreased by 37%, and left ventricular end-diastolic pressure decreased by 78%. Urine output increased by ∼9-fold after 15 minutes of support. No device malfunction or procedural or device-related adverse events occurred. There was no evidence of pump thrombosis. All 4 patients were alive at 30 days. Conclusions: This first-in-human study demonstrated the feasibility and safety of cardiorenal support with ModulHeart among patients undergoing high-risk PCI. ModulHeart demonstrated significant improvement in cardiac output, left ventricular end-diastolic pressure, and urine output. Future studies are planned to assess outcomes associated with ModulHeart support in patients with heart failure.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.