Evidence map›Paper›PMID 39132369›Full record

ArticleJournal of the Society for Cardiovascular Angiography & Interventions

First-in-Human Experience With the ModulHeart Device for Mechanical Circulatory Support and Renal Perfusion.

Gabriel Georges, François Trudeau, Jade Doucet-Martineau, Maxime Rochon, Jeannot Potvin, Adrian Ebner, Philippe Généreux

Abstract read
In one paragraph

Article in Journal of the Society for Cardiovascular Angiography & Interventions. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Review
  2. Contemporary overview of current percutaneous mechanical circulatory support devices for advanced heart failure: a narrative review.Kardiochirurgia i torakochirurgia polska = Polish journal of cardio-thoracic surgery · 2026
    Review
  3. Article
  4. Review
  5. Review
  6. A Novel Transaortic Pulsatile Pump to Unload the Left Ventricle.JACC. Basic to translational science · 2025
    Article
  7. Review
  8. Article
  9. Innovative Intra-Aortic Circulatory Support Pump: Novel Hemodynamics.Journal of the Society for Cardiovascular Angiography & Interventions
    Article
  10. Emerging Device Therapies for Cardiorenal Syndrome.Journal of the Society for Cardiovascular Angiography & Interventions
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Gabriel GeorgesQuebec Heart and Lung Institute, Quebec, Quebec, Canada.
François TrudeauPuzzle Medical Devices Inc, Montreal, Quebec, Canada.
Jade Doucet-MartineauPuzzle Medical Devices Inc, Montreal, Quebec, Canada.
Maxime RochonPuzzle Medical Devices Inc, Montreal, Quebec, Canada.
Jeannot PotvinCentre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada.
Adrian EbnerSanatorio Italiano, Asuncion, Paraguay.
Philippe GénéreuxGagnon Cardiovascular Institute, Morristown Medical Center, Morristown, New Jersey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: ModulHeart (Puzzle Medical Devices Inc) is a modular device providing hemodynamic support through 3 endovascular pumps inserted in series and assembled in parallel into a self-expandable anchor implanted in the descending aorta. The current study evaluates the feasibility and safety of cardiorenal support with ModulHeart among patients undergoing high-risk percutaneous coronary intervention (PCI). Methods: This study was a prospective, single-center, first-in-human study. The primary end point was procedural success, defined as successful delivery, function, and removal of the ModulHeart device. Secondary end points included pump hemodynamics, cardiac hemodynamics, and urine output. Results: On June 28 and 29, 2022, 4 patients were enrolled and underwent high-risk PCI with ModulHeart implanted via transfemoral approach. All 4 patients achieved procedural success. The mean delivery time was 8 minutes, the mean support time was 49 minutes, and the mean pump removal time was 7 minutes. The mean pressure gradient across the pump was 5 ± 2 mm Hg. Under ModulHeart support, cardiac index increased by 25%, central venous pressure decreased by 37%, and left ventricular end-diastolic pressure decreased by 78%. Urine output increased by ∼9-fold after 15 minutes of support. No device malfunction or procedural or device-related adverse events occurred. There was no evidence of pump thrombosis. All 4 patients were alive at 30 days. Conclusions: This first-in-human study demonstrated the feasibility and safety of cardiorenal support with ModulHeart among patients undergoing high-risk PCI. ModulHeart demonstrated significant improvement in cardiac output, left ventricular end-diastolic pressure, and urine output. Future studies are planned to assess outcomes associated with ModulHeart support in patients with heart failure.

Indexed as

first-in-humanheart failureleft ventricular assist devicemechanical circulatory supportpercutaneous coronary intervention

Identifiers

PMID39132369
PMCPMC11307613

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.