Evidence map›Paper›PMID 39132331›Full record

ArticleCirculation reports2024

Long-Term Outcomes in Patients With Relatively High His-Bundle Capture Threshold After Permanent His-Bundle Pacing - A Multicenter Clinical Study.

Ryo Watanabe, Hiroyuki Kato, Satoshi Yanagisawa, Taku Sakurai, Ryusuke Ota, Hisashi Murakami, Kenji Kada, Naoya Tsuboi, Yasuya Inden, Rei Shibata and 1 more

Abstract read
In one paragraph

Article in Circulation reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Ryo WatanabeDepartment of Cardiology, Japanese Red Cross Aichi Medical Center Nagoya Daini Hospital Nagoya Japan.
Hiroyuki KatoDivision of Cardiology, Japan Community Health Care Organization Chukyo Hospital Nagoya Japan.
Satoshi YanagisawaDepartment of Cardiology, Nagoya University Graduate School of Medicine Nagoya Japan.
Taku SakuraiDivision of Cardiology, Japan Community Health Care Organization Chukyo Hospital Nagoya Japan.
Ryusuke OtaDivision of Cardiology, Japan Community Health Care Organization Chukyo Hospital Nagoya Japan.
Hisashi MurakamiDivision of Cardiology, Japan Community Health Care Organization Chukyo Hospital Nagoya Japan.
Kenji KadaDivision of Cardiology, Japan Community Health Care Organization Chukyo Hospital Nagoya Japan.
Naoya TsuboiDivision of Cardiology, Japan Community Health Care Organization Chukyo Hospital Nagoya Japan.
Yasuya IndenDepartment of Cardiology, Nagoya University Graduate School of Medicine Nagoya Japan.
Rei ShibataDepartment of Advanced Cardiovascular Therapeutics, Nagoya University Graduate School of Medicine Nagoya Japan.
Toyoaki MuroharaDepartment of Cardiology, Nagoya University Graduate School of Medicine Nagoya Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Outcomes in patients with relatively high His-bundle (HB) capture thresholds at implantation are unknown. This study aimed to compare changes in the HB capture threshold and prognosis between patients with a relatively high threshold and those with a low threshold. Methods and Results: Forty-nine patients who underwent permanent HB pacing (HBP) were divided into two groups: low (<1.25 V at 1.0 ms; n=35) and high (1.25-2.49 V; n=14) baseline HB capture threshold groups. The HB capture threshold was evaluated at implantation, and after 1 week, 1, 3, and 6 months, and every 6 months thereafter. HB capture threshold rise was defined as threshold rise ≥1.0 V at 1.0 ms compared with implantation measures. We compared outcomes between the groups. During a mean follow-up period of 34.6 months, the high-threshold group showed a trend toward a higher incidence of HB capture threshold of ≥2.5 V (50% vs. 14%; P=0.023), HBP abandonment (29% vs. 8.6%; P=0.091), lead revision (21% vs. 2.9%; P=0.065), and clinical events (all-cause death, heart failure hospitalization, and new-onset or progression of atrial fibrillation; 50% vs. 23%; P=0.089) than the low-threshold group. A baseline HB capture threshold of ≥1.25V was an independent predictor of clinical events. Conclusions: A relatively high HB capture threshold is associated with increased risk of HBP abandonment, lead revision, and poor clinical outcomes.

Indexed as

Conduction system pacingHis-bundle capture thresholdHis-bundle pacingLead abandonLead revision

Identifiers

PMID39132331
PMCPMC11309777

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.