Evidence map›Paper›PMID 39131646›Full record

ArticleJournal of the Society for Cardiovascular Angiography & Interventions

One-year Outcomes of XIENCE Skypoint 48-mm Drug-Eluting Stents in Long Coronary Lesions: The SPIRIT 48 Trial.

Ki E Park, Chiung-Jen Wu, Bassem Chehab, Aziz Maksoud, Barry Bertolet, Shih-Wa Ying, Tiessa Simoes, Sandeep C Pingle, Chi-Jen Chang

Registry-linked trialAbstract read
In one paragraph

Article in Journal of the Society for Cardiovascular Angiography & Interventions. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07399002 (Long Coronary Lesions), which is not on this map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07399002 recruitingnot on this map

Long Coronary Lesions: Safety and Performance of the Ultimaster Nagomi™ Stent in This Setting With a One-to-one Approach -One Lesion, One Stent- LONG NAGOMI™ PMCF STUDY

Typeobservational_patient_registrySponsorFundación EPICRan2026 to 2029Enrolled1,039ConditionsCoronary Artery Disease, Ischemic Heart DiseaseArmsLONG NAGOMI
3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ki E ParkDivision of Cardiovascular Medicine, Malcom Randall VA Medical Center, University of Florida, Gainesville, Florida.
Chiung-Jen WuDepartment of Cardiology, Chung-Gung Memorial Hospital, Kaohsiung, Taiwan.
Bassem ChehabDepartment of Medicine, Ascension Via Christi Hospital, University of Kansas, Wichita, Kansas.
Aziz MaksoudDepartment of Medicine, Cardiovascular Research Institute of Kansas, University of Kansas, Wichita, Kansas.
Barry BertoletCardiac Catheterization Laboratory, North Mississippi Medical Center, Tupelo, Mississippi.
Shih-Wa YingAbbott Vascular, Santa Clara, California.
Tiessa SimoesAbbott Vascular, Santa Clara, California.
Sandeep C PingleAbbott Vascular, Santa Clara, California.
Chi-Jen ChangCardiovascular Division, Department of Internal Medicine, Chang Gung Memorial Hospital, Tapei, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Diffuse coronary artery disease may need multiple overlapping stents, associated with less favorable outcomes than those of a single stent. The availability of longer stents can circumvent the need for overlapping stents in long lesions. This prospective, single-arm, SPIRIT 48 trial evaluated the safety and effectiveness of Abbott's next-generation drug-eluting stent, XIENCE Skypoint 48, in patients with coronary artery disease with long de novo native coronary lesions. Methods: SPIRIT 48 enrolled 107 patients at 25 sites in 3 countries. Patients were required to have 1 target lesion treated with XIENCE Skypoint 48 (lesion length of >32.0 mm and ≤44.0 mm). The primary end point was target lesion failure (TLF; composite of cardiac death, target vessel-related myocardial infarction, or clinically indicated target lesion revascularization) at the 1-year compared with a prespecified performance goal of 20%, established through historical control data. This study recently completed its 1-year follow-up. Results: XIENCE Skypoint 48 was implanted in 105 patients with a device success rate of 97.2%. SPIRIT 48 met its primary end point, with a TLF rate of 5.7%, and the upper bound of 95% CI at 9.5% (<performance goal of 20%). This was associated with a low rate of 5.8% (6/104 patients) for cardiac death/all myocardial infarction at 1 year. Definite or probable device thrombosis at 1 year occurred in only 1 subject (1.0%). Conclusions: Primary end point data obtained at the 1-year follow-up from the SPIRIT 48 trial present strong evidence supporting the deliverability, safety, and effectiveness of XIENCE Skypoint 48 mm drug-eluting stent in treating long de novo coronary lesions.

Indexed as

coronary diseasedrug-eluting stentspercutaneous coronary intervention

Identifiers

PMID39131646
PMCPMC11308516

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials