ArticleJournal of medical physics

Evaluation of the Treatment Planning and Delivery for Hip Implant Cases on Tomotherapy.

Pawan Kumar Singh, Rohit Verma, Deepak Tripathi, Sukhvir Singh, Manindra Bhushan, Lalit Kumar, Soumitra Barik, Munish Gairola

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Pawan Kumar SinghDepartment of Physics, Amity Institute of Applied Sciences, Amity University (AUUP), Noida, India.
Rohit VermaDepartment of Physics, Amity Institute of Applied Sciences, Amity University (AUUP), Noida, India.
Deepak TripathiDepartment of Physics, USAR, Guru Gobind Singh Indraprastha University, East Campus, Delhi, India.
Sukhvir SinghRadiation Safety Group, Institute of Nuclear Medicine and Allied Sciences, Defence Research and Development Organisation, New Delhi, India.
Manindra BhushanDepartment of Radiation Oncology and Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India.
Lalit KumarDepartment of Radiation Oncology, Max Super Speciality Hospital, New Delhi, India.
Soumitra BarikDepartment of Radiation Oncology and Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India.
Munish GairolaDepartment of Radiation Oncology and Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The metal present in the implant creates artifacts during the treatment simulation, which impacts the treatment planning and delivery of the prescribed dose to the target and sparing normal tissues. This retrospective study evaluated the uncertainties in the planning and delivery of doses for prosthesis cases with dedicated phantom. Materials and Methods: In this retrospective study, 11 patients with a hip prosthesis having cervix carcinoma were selected. Two treatment plans were generated on treatment planning system (TPS) for each case. Plan_No_Res was without any beam restriction, and Plan_exit_only was the plan with restricted beam entry through the metallic implant. An indigenous phantom was utilized to verify the accuracy of the treatment. In the phantom, some groves were present, which could be filled by implants that mimic the patient's geometries, like left, right and bilateral femur implants. The delivered doses were recorded using optically stimulated luminescence dosimeters (OSLDs), which were placed at different positions in the phantom. The plans were further calculated using megavoltage computed tomography (MVCT) scans acquired during treatment. Results: The patient data showed no significant dose changes between the two planning methods. The treatment time increases from 412.18 ± 86.65 to 427.36 ± 104.80 with Conclusion: The study showed the competency of tomotherapy planning for hip prosthesis cases. The phantom measurements demonstrate the errors in dosimetry near the implant material, suggesting the need for precise methods to deal with artifact-related issues.

Indexed as

Hip prosthesismegavoltage computed tomographymetallic implantOSLDtomotherapy

Identifiers

PMID39131420
PMCPMC11309148

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.