ArticleZeitschrift fur medizinische Physik2025
Reducing electromagnetic interference in MR thermometry: A comparison of setup configurations for MR-guided microwave ablations.
Article in Zeitschrift fur medizinische Physik, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- A Magnetic Resonance Fingerprinting Approach for SimultaneousMagnetic resonance in medicine · 2026Article
- Evaluation study of radial and spiral based volumetric thermometry for monitoring of hepatic microwave ablation.Scientific reports · 2025Article
- Image-Based Monitoring of Thermal Ablation.Bioengineering (Basel, Switzerland) · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Magnetic Resonance (MR) thermometry is used for the monitoring of MR-guided microwave ablations (MWA), and for the intraoperative evaluation of ablation regions. Nevertheless, the accuracy of temperature mapping may be compromised by electromagnetic interference emanating from the microwave (MW) generator. This study evaluated different setups for improving magnetic resonance imaging (MRI) during MWA with a modified MW generator. MWA was performed in 15 gel phantoms comparing three setups: The MW generator was placed outside the MR scanner room, either connected to the MW applicator using a penetration panel with a radiofrequency (RF) filter and a 7 m coaxial cable (Setup 1), or through a waveguide using a 5 m coaxial cable (Setup 2). Setup 3 employed the MW generator within the MR scan room, connected by a 5 m coaxial cable. The coaxial cables in setups 2 and 3 were modified with custom shielding to reduce interference. The setups during ablation (active setup) were compared to a reference setup without the presence of the MW system. Thermometry and thermal dose maps (CEM43 model) were compared for the three configurations. Primary endpoints for assessment were signal-to-noise ratio (SNR), temperature precision, Sørensen-Dice-Coefficient (DSC), and RF-noise spectra. Setup 3 showed highly significant electromagnetic interference during ablation with a SNR decrease by -60.4%±13.5% (p<0.001) compared to reference imaging. For setup 1 and setup 2 no significant decrease in SNR was measured with differences of -2.9%±9.8% (p=0.6) and -1.5%±12.8% (p=0.8), respectively. SNR differences were significant between active setups 1 and 3 with -51.2%±16.1% (p<0.001) and between active setups 2 and 3 with -59.0%±15.5% (p<0.001) but not significant between active setups 1 and 2 with 19.0%±13.7% (p=0.09). Furthermore, no significant differences were seen in temperature precision or DSCs between all setups, ranging from 0.33 °C ± 0.04 °C (Setup 1) to 0.38 °C ± 0.06 °C (Setup 3) (p=0.6) and from 87.0%±1.6% (Setup 3) to 88.1%±1.6% (Setup 2) (p=0.58), respectively. Both setups (1 and 2) with the MW generator outside the MR scanner room were beneficial to reduce electromagnetic interference during MWA. Moreover, provided that a shielded cable is utilized in setups 2 and 3, all configurations displayed negligible differences in temperature precision and DSCs, indicating that the location of the MW generator does not significantly impact the accuracy of thermometry during MWA.