Evidence map›Paper›PMID 39128972›Full record

ArticleThe international journal of cardiovascular imaging2024

Dual-source photon-counting computed tomography for coronary in-stent observation: influence of heart rate and virtual monoenergetic image.

Ryo Ogawa, Masahiro Yanagawa, Akinori Hata, Kazuki Yamagata, Keisuke Ninomiya, Shuhei Doi, Noriko Kikuchi, Yukiko Tokuda, Misato Chimura, Daisuke Nakamura and 3 more

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Ryo OgawaDepartment of Future Diagnostic Radiology, Osaka University Graduate School of Medicine, Yamadaoka, 2-2, Suita, Osaka, 565-0871, Japan. r-ogawa@radiol.med.osaka-u.ac.jp.
Masahiro YanagawaDepartment of Radiology, Osaka University Graduate School of Medicine, Yamadaoka, 2-2, Suita, Osaka, 565-0871, Japan.
Akinori HataDepartment of Radiology, Osaka University Graduate School of Medicine, Yamadaoka, 2-2, Suita, Osaka, 565-0871, Japan.
Kazuki YamagataDepartment of Radiology, Osaka University Graduate School of Medicine, Yamadaoka, 2-2, Suita, Osaka, 565-0871, Japan.
Keisuke NinomiyaDepartment of Radiology, Osaka University Graduate School of Medicine, Yamadaoka, 2-2, Suita, Osaka, 565-0871, Japan.
Shuhei DoiDepartment of Radiology, Osaka University Graduate School of Medicine, Yamadaoka, 2-2, Suita, Osaka, 565-0871, Japan.
Noriko KikuchiDepartment of Radiology, Osaka University Graduate School of Medicine, Yamadaoka, 2-2, Suita, Osaka, 565-0871, Japan.
Yukiko TokudaDepartment of Radiology, Osaka University Graduate School of Medicine, Yamadaoka, 2-2, Suita, Osaka, 565-0871, Japan.
Misato ChimuraDepartment of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Yamadaoka, 2-2, Suita, Osaka, 565-0871, Japan.
Daisuke NakamuraDepartment of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Yamadaoka, 2-2, Suita, Osaka, 565-0871, Japan.
Toshihide ItohDepartment of CT Research and Collaboration, Siemens Healthineers, 1-11-1 Osaki, Shinagawa, Tokyo, 141-8644, Japan.
Teruhito KidoDepartment of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon-City, Ehime, 791-0295, Japan.
Noriyuki TomiyamaDepartment of Radiology, Osaka University Graduate School of Medicine, Yamadaoka, 2-2, Suita, Osaka, 565-0871, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To investigate the effect of heart rate and virtual monoenergetic image (VMI) on coronary stent imaging in dual-source photon-counting detector computed tomography (PCD-CT). A dynamic cardiac phantom was used to vary the heart rate at 50 beats per minute (bpm), 70 bpm, and 90 bpm. Five types of stents (4.0 mm, 3.5 mm, 3.0 mm, 2.75 mm, and 2.5 mm diameter) were scanned at three different locations and reconstructed VMI at 70 keV. In addition, 50% stenosis was assessed for 3.0 mm and 4.0 mm stents. To assess in-stent stenosis, 40 keV, 70 keV, and 100 keV images were compared. Measurable lumen and contrast to noise ratio (CNR) from lumen to stenosis were evaluated quantitatively. A-4-point scale was used for the qualitative image quality of in-stent stenosis. The measurable lumen had no significant differences among heart rates in patent stents (p = 0.55). In-stent stenosis, the residual lumen was significantly larger in 40 keV [27.5% (20.8-32.3%)] than in 70 keV [11.5% (10.0-23.0%), p < 0.05] and 100 keV [0% (0-5.2%), p < 0.05]. The CNR was higher in 40 keV [12.5 (7.5-18.2)] than in 70 keV [5.3 (2.9-7.7), p < 0.05] and 100 keV [1.3 (0.5-2.7), p < 0.05]. The image quality was better in 40 keV (3.4 ± 0.7) than in 70 keV [(2.6 ± 0.8), p < 0.05] and 100 keV [(1.3 ± 0.4), p < 0.05]. Dual-source PCD-CT maintains a measurable lumen even at high heart rates. Adjusting the VMI can be helpful in visualizing the in-stent stenosis.

Indexed as

Computed Tomography AngiographyCoronary AngiographyCoronary VesselsHeart RatePhantoms, ImagingPredictive Value of TestsRadiographic Image Interpretation, Computer-AssistedStentsCoronary RestenosisCoronary StenosisHumansPercutaneous Coronary InterventionPhotonsProsthesis DesignReproducibility of ResultsCoronary stentDual-source CTPhoton-counting CTVirtual monoenergetic image

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.