ArticleScientific reports2024
High pressure sensor based on intensity-variation using polymer optical fiber.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Impact of boundary conditions and geometric tolerances dynamics on MEMS double touch mode capacitance pressure sensor applying M-shaped silicon design.Scientific reports · 2026Article
- Review
- The Design and Validation of an Intensity-Modulated Multipoint Fiber-Optic Liquid-Level Sensor.Sensors (Basel, Switzerland) · 2025Article
- Exhaustive analysis and simple model of an angular displacement optical fiber sensor.Scientific reports · 2025Article
- Simultaneous measurement of liquid level and R.I. sensor using POF based on twisted structure.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
Silica fiber under high pressure increases the risk of fiber breakage or permanent deformation, which may cause sensor failure due to mechanical strength limitations. High pressure can also induce birefringence in optical fiber. In this study, we present a simple design and low-cost high pressure sensor using polymer optical fiber (POF) based on the intensity-variation technique. A side-coupling mechanism in the sensor structure is adopted, which varies the intensity with applied pressure. Two POFs are twisted together to create a sensing region where the light is launched in the first fiber and measurement is taken from the second fiber. In sensing phenomena, cladding mode frustrated total internal reflection occurs when pressure increases. Silicone gel is used in the pressure chamber for sealing and preventing leakage. The sensor structure is able to detect high pressure in the MPa range, where we tested up to 4 MPa. For higher sensitivity, twisted and bend structure is analyzed, and sensitivity is achieved at about 432.21 nW/MPa. However, twisted helical structure is adopted to enhance sensing range which is about 50 cm. The proposed high-pressure sensor structure is easier to fabricate and has high stability because it doesn't require any destructive method as compared to other conventional methods.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.