Observational studyDiabetologia2024
Accuracy of continuous glucose monitoring in the hospital setting: an observational study.
Observational study in Diabetologia, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Perioperative use and accuracy of continuous glucose monitoring: A systematic review.Diabetes, obesity & metabolism · 2025Pooled it
- An international position statement on practical approaches for inpatient continuous glucose monitoring, insulin pumps and automated insulin delivery systems in adults.Diabetologia · 2026Article
- Time delays between fingerstick glucose measurements and correctional insulin administration in the hospital: do they really matter?Diabetologia · 2026Observational
- A Flexible Wearable Glucose Sensor for Noninvasive Diabetes Screening: Functional Equivalence and Model Interpretability.Biosensors · 2026Article
- Understanding Glycemia in the Post Discharge Period Through Blinded Continuous Glucose Monitoring.Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2026Observational
- Accuracy and Clinical Safety of the FreeStyle Libre 2 System in an Internal Medicine Intermediate Care Unit.Cureus · 2026Article
- Inpatient Diet Orders and Continuous Glucose Monitoring in Noncritically Ill, Hospitalized Adult Patients.Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2026Observational
- Association of continuous glucose monitoring with in-hospital adverse outcomes among critically ill patients: a real-world propensity score-matched study.Frontiers in endocrinology · 2026Article
- Feasibility of continuous glucose monitoring in children with diabetic ketoacidosis: an exploratory observational study.European journal of pediatrics · 2025Observational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
Abstract
aims/hypothesisContinuous glucose monitoring (CGM) improves glycaemic outcomes in the outpatient setting; however, there are limited data regarding CGM accuracy in hospital.
methodsWe conducted a prospective, observational study comparing CGM data from blinded Dexcom G6 Pro sensors with reference point of care and laboratory glucose measurements during participants' hospitalisations. Key accuracy metrics included the proportion of CGM values within ±20% of reference glucose values >5.6 mmol/l or within ±1.1 mmol/l of reference glucose values ≤5.6 mmol/l (%20/20), the mean and median absolute relative difference between CGM and reference value (MARD and median ARD, respectively) and Clarke error grid analysis (CEGA). A retrospective calibration scheme was used to determine whether calibration improved sensor accuracy. Multivariable regression models and subgroup analyses were used to determine the impact of clinical characteristics on accuracy assessments.
resultsA total of 326 adults hospitalised on 19 medical or surgical non-intensive care hospital floors were enrolled, providing 6648 matched glucose pairs. The %20/20 was 59.5%, the MARD was 19.2% and the median ARD was 16.8%. CEGA showed that 98.2% of values were in zone A (clinically accurate) and zone B (benign). Subgroups with lower accuracy metrics included those with severe anaemia, renal dysfunction and oedema. Application of a once-daily morning calibration schedule improved accuracy (MARD 11.4%). CONCLUSIONS/
interpretationThe CGM accuracy when used in hospital may be lower than that reported in the outpatient setting, but this may be improved with appropriate patient selection and daily calibration. Further research is needed to understand the role of CGM in inpatient settings.