Evidence map›Paper›PMID 39125511›Full record

ArticleDiagnostics (Basel, Switzerland)2024

Early Detection of Heart Failure with Autonomous AI-Based Model Using Chest Radiographs: A Multicenter Study.

Emiliano Garza-Frias, Parisa Kaviani, Lina Karout, Roshan Fahimi, Seyedehelaheh Hosseini, Preetham Putha, Manoj Tadepalli, Sai Kiran, Charu Arora, Dennis Robert and 4 more

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Emiliano Garza-FriasDepartment of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
Parisa KavianiDepartment of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.ORCID 0000-0003-0911-7507
Lina KaroutDepartment of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
Roshan FahimiDepartment of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
Seyedehelaheh HosseiniDepartment of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
Preetham PuthaQure AI, Mumbai 400063, India.
Manoj TadepalliQure AI, Mumbai 400063, India.ORCID 0000-0002-8632-9231
Sai KiranQure AI, Mumbai 400063, India.
Charu AroraQure AI, Mumbai 400063, India.
Dennis RobertQure AI, Mumbai 400063, India.ORCID 0000-0002-8539-6408
Bernardo BizzoDepartment of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
Keith J DreyerDepartment of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
Mannudeep K KalraDepartment of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
Subba R DigumarthyDepartment of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.

Funding

Qure.AI No grant number was used
6 · The paper itself

Abstract

The opportunistic use of radiological examinations for disease detection can potentially enable timely management. We assessed if an index created by an AI software to quantify chest radiography (CXR) findings associated with heart failure (HF) could distinguish between patients who would develop HF or not within a year of the examination. Our multicenter retrospective study included patients who underwent CXR without an HF diagnosis. We included 1117 patients (age 67.6 ± 13 years; m:f 487:630) that underwent CXR. A total of 413 patients had the CXR image taken within one year of their HF diagnosis. The rest (n = 704) were patients without an HF diagnosis after the examination date. All CXR images were processed with the model (qXR-HF, Qure.AI) to obtain information on cardiac silhouette, pleural effusion, and the index. We calculated the accuracy, sensitivity, specificity, and area under the curve (AUC) of the index to distinguish patients who developed HF within a year of the CXR and those who did not. We report an AUC of 0.798 (95%CI 0.77-0.82), accuracy of 0.73, sensitivity of 0.81, and specificity of 0.68 for the overall AI performance. AI AUCs by lead time to diagnosis (<3 months: 0.85; 4-6 months: 0.82; 7-9 months: 0.75; 10-12 months: 0.71), accuracy (0.68-0.72), and specificity (0.68) remained stable. Our results support the ongoing investigation efforts for opportunistic screening in radiology.

Indexed as

artificial intelligencechest radiographheart failureopportunistic screening

Identifiers

PMID39125511
PMCPMC11311468

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.