Evidence map›Paper›PMID 39125219›Full record

ArticlePolymers2024

Polymeric Protective Films as Anticorrosive Coatings-Environmental Evaluation.

Alina Ruxandra Caramitu, Romeo Cristian Ciobanu, Magdalena Valentina Lungu, Eduard-Marius Lungulescu, Cristina Mihaela Scheiner, Mihaela Aradoaei, Adriana Mariana Bors, Traian Rus

Abstract read
In one paragraph

Article in Polymers, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Alina Ruxandra CaramituNational Institute for Research and Development in Electrical Engineering ICPE-CA Bucharest, 030168 Bucharest, Romania.ORCID 0000-0002-7751-9324
Romeo Cristian CiobanuDepartment of Electrical Measurements and Materials, Gheorghe Asachi Technical University, 700050 Iasi, Romania.
Magdalena Valentina LunguNational Institute for Research and Development in Electrical Engineering ICPE-CA Bucharest, 030168 Bucharest, Romania.ORCID 0000-0002-5399-6847
Eduard-Marius LungulescuNational Institute for Research and Development in Electrical Engineering ICPE-CA Bucharest, 030168 Bucharest, Romania.ORCID 0000-0002-2485-716X
Cristina Mihaela ScheinerDepartment of Electrical Measurements and Materials, Gheorghe Asachi Technical University, 700050 Iasi, Romania.
Mihaela AradoaeiDepartment of Electrical Measurements and Materials, Gheorghe Asachi Technical University, 700050 Iasi, Romania.ORCID 0000-0002-9173-9817
Adriana Mariana BorsNational Research and Development Institute for Optoelectronics INOE 2000-IHP Bucharest, 077125 Măgurele, Romania.ORCID 0000-0003-4928-8159
Traian RusDepartment of Inorganic Chemistry, Physical Chemistry and Electrochemistry, National University of Science and Technology-Politehnica Bucharest, Splaiul Independentei No. 313, 060042 Bucharest, Romania.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The behavior of two polymeric protective paint coatings (epoxy and polyurethane) applied over an epoxy primer coating on steel plates was investigated in this study, focusing on their role in providing anticorrosive protection against various climatic stress factors. Among the numerous climatic factors that can affect the lifetime of anticorrosive coatings, the following were selected for this work: dry heat, UV radiation, humidity, and extreme conditions such as salt fog, marine atmosphere, and alpine atmosphere. The objective was to determine the remaining lifetime of these protective coatings before replacement is needed to prevent damage to the equipment they protect. The behavior of these polymeric materials under the mentioned factors was analyzed based on the variation in the tangent of the dielectric loss angle (tg δ) with frequency. From the interpretation of the experimental results, it was found that the polyurethane paint coating (P2) exhibits superior resistance to climatic degradation compared to the epoxy paint coating (P1). Furthermore, a comparison of tg δ values for the P1 and P2 coatings revealed that the initial (unaged) P2 coating performs better as an insulator (dielectric) than the P1 coating. Comprehensive information is provided to the users of polymeric anticorrosive protection materials, highlighting the extent to which climatic factors can affect the performance of the equipment they protect and determining the appropriate timing for replacing the coatings.

Indexed as

corrosion protectiondefraud factorspolymeric coatings

Identifiers

PMID39125219
PMCPMC11314705

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.