ArticleSensors (Basel, Switzerland)2024
Lightning Current Measurement Method Using Rogowski Coil Based on Integral Circuit with Low-Frequency Attenuation Feedback.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Autonomous Lightning Strike Detection and Counting System Using Rogowski Coil Current Measurement.Sensors (Basel, Switzerland) · 2025Article
- Fully Printed and Scalable Current and Voltage Sensors for Smart Grid Transmission Line Monitoring.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
A lightning current measurement method using a Rogowski coil based on an integral circuit with low-frequency attenuation feedback was proposed to address the issue of low-frequency distortion in the measurement of lightning currents on transmission lines using Rogowski coils. Firstly, the causes of low-frequency distortion in lightning current measurements using Rogowski coils were analyzed from the perspective of frequency domains. On this basis, an integration correction optimization circuit with a low-frequency attenuation feedback network was designed to correct the low-frequency distortion. The optimized integration circuit can also reduce the impact of low-frequency noise and the DC bias of the operational amplifier (op-amp) on the integration circuit due to the high low-frequency gain. Additionally, a high-pass filtering and voltage-divided sampling circuit has been added to ensure the normal operation of the integrator and improve the measurement range of the measurement system. Then, according to the relationship between the amplitude-frequency characteristics of the measurement system and the parameters of each component, the appropriate types of components and op-amp were selected to expand the measurement bandwidth. Finally, a simulation verification was conducted, and the simulation results show that this measurement method can effectively expand the lower measurement frequency limit to 20 Hz, correct the low-frequency distortion caused by Rogowski coils measuring lightning currents on transmission lines, and accurately restore the measured lightning current waveform.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.