Evidence map›Paper›PMID 39123814›Full record

ArticleSensors (Basel, Switzerland)2024

Strategy and Metrological Support for Indoor Radon Measurements Using Popular Low-Cost Active Monitors with High and Low Sensitivity.

Andrey Tsapalov, Konstantin Kovler, Peter Bossew

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Andrey TsapalovNational Building Research Institute, Faculty of Civil and Environmental Engineering, Technion, Israel Institute of Technology, Haifa 3200003, Israel.ORCID 0000-0002-5875-381X
Konstantin KovlerNational Building Research Institute, Faculty of Civil and Environmental Engineering, Technion, Israel Institute of Technology, Haifa 3200003, Israel.ORCID 0000-0002-8227-8975
Peter BossewRetired, 1090 Vienna, Austria.ORCID 0000-0003-3924-8815

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Traditionally, for indoor radon testing, predominantly passive measurements have been used, typically applying the solid-state alpha track-etch method for long-term and the charcoal method for short-term measurements. However, increasingly, affordable consumer-grade active monitors have become available in the last few years, which can generate a concentration time series of an almost arbitrary duration. Firstly, we argue that consumer-grade monitors can well be used for quality-assured indoor radon assessment and consequent reliable decisions. Secondly, we discuss the requirements of quality assurance, which actually allow for reliable decision-making. In particular, as part of a rational strategy, we discuss how to interpret measurement results from low-cost active monitors with high and low sensitivity with respect to deciding on conformity with reference levels that are the annual average concentration of indoor radon. Rigorous analysis shows that temporal variations in radon are a major component of the uncertainty in decision-making, the reliability of which is practically independent of monitor sensitivity. Manufacturers of low-cost radon monitors already provide sufficient reliability and quality of calibration for their devices, which can be used by both professional inspectors and the general public. Therefore, within the suggested measurement strategy and metrologically assured criteria, we only propose to clarify the set and values of the key metrological characteristics of radon monitors as well as to upgrade user-friendly online tools. By implementing clear metrological requirements as well as the rational measurement strategy for the reliable conformity assessment of a room (building) with radon safety requirements, we anticipate significant reductions in testing costs, increased accessibility, and enhanced quality assurance and control (QA/QC) in indoor radon measurements.

Indexed as

calibrationconformity assessmentcontinuous radon monitorsdecision-makingindoor radonmeasurement uncertaintymetrologyQA/QCsensitivitytemporal variation

Identifiers

PMID39123814
PMCPMC11314910

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.