Evidence map›Paper›PMID 39123117›Full record

ArticleBMC infectious diseases2024

Field-applicable simultaneous multiplex LAMP assay for screening HBV and HCV co-infection in a single tube.

Esra Agel, Kevser Hanne Altın

Abstract read
In one paragraph

Article in BMC infectious diseases, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Esra AgelScientific and Technological Research Council of Türkiye, Sensor Technologies Research Group TUBITAK Marmara Research Center, Gebze, Kocaeli, 41470, Türkiye. esra.agel@tubitak.gov.tr.ORCID http://orcid.org/0000-0002-8434-3232
Kevser Hanne AltınDepartment of Medical Microbiology, Istanbul Medipol University, Beykoz, Istanbul, 34815, Türkiye.ORCID http://orcid.org/0000-0001-6068-3892

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundGlobally, around 7 to 20 million people are believed to be suffering from coinfection with both hepatitis B virus (HBV) and hepatitis C virus (HCV). The loop-mediated isothermal amplification (LAMP) approach, introduced by Notomi and colleagues, has undergone substantial advancements as an effective molecular tool that enables the simultaneous analysis of multiple samples in a single tube.

methodsThe present study examined the simultaneous detection of HBV and HCV in a single tube using melt curve analysis multiplex LAMP (mLAMP), which is based on the identification of unique melting peak temperatures. Selected regions for primer design including the S gene of HBV and the UTR gene of HCV. Primer optimization is initially performed through individual HBV and HCV LAMP analysis. Following the optimization process, the mLAMP assay was evaluated by optimizing the multiplex reaction mixture, determining the reaction time, and analyzing the limit of detection (LOD). The results are also analyzed using lateral flow dipsticks (LFD), which enable the visual detection of HBV and HCV by adding 20 pmol FITC-labeled LF primers into the reaction mixture prior the mLAMP.

resultsThe LOD for the mLAMP assay was determined as 10 copies/µl, and no cross-reactivity with other microorganisms was detected. The detection results obtained from patient plasma were also visually demonstrated using LFD, and displayed significant concordance with those obtained from Real-Time Polymerase Chain Assay. The mLAMP assay revealed a diagnostic sensitivity of 95% for detecting the HBV, and LOD is 90% for HCV. The overall diagnostic sensitivity of the mLAMP assay for both viruses was 85%. The assay confirmed a specificity of 100%.

conclusionThe mLAMP assay displays significant promise for analyzing coinfected samples by simultaneously detecting the dual targets HBV and HCV within a set temperature of 62 °C, all within a time frame of 1 h. Additionally, when paired with disposable LFD, the mLAMP assay enables rapid visual detection of assay results in a matter of minutes. The result contributes to the mLAMP assay being highly suitable for coinfection screening, particularly in field conditions.

Indexed as

CoinfectionHepacivirusHepatitis BHepatitis B virusHepatitis CMolecular Diagnostic TechniquesNucleic Acid Amplification TechniquesSensitivity and SpecificityDNA PrimersHumansLimit of DetectionDNA PrimersIsothermal amplificationLateral flow dipstickMultiplex LAMPPoint of careRapid diagnostics

Identifiers

PMID39123117
PMCPMC11311944

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.