Observational studyAJNR. American journal of neuroradiology2024
Multicenter Experience with the Pipeline Flex and Vantage with Shield Technology for Intracranial Aneurysm Treatment.
Observational study in AJNR. American journal of neuroradiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Midterm Results on Pipeline Vantage Embolization Device (MR-PVED): First Reported Experience in Asia.Asian journal of neurosurgery · 2026Article
- Light Transmission Aggregometry Versus VerifyNow for Antiplatelet Monitoring in Flow Diversion: A Retrospective Comparative Study.Diagnostics (Basel, Switzerland) · 2026Article
- Efficacy and Safety in the Use of Pipeline Vantage Shield Stent versus Pipeline Flex Shield Stent in the Treatment of Patients with Unruptured Intracranial Aneurysms: A Multicenter Study.AJNR. American journal of neuroradiology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeThe Pipeline Embolization Device is a safe and effective treatment option for intracranial aneurysms. The newer Pipeline generations have received structural refinements and a surface modification to improve deliverability, procedural safety, and angiographic outcomes. This multicenter study evaluated the clinical safety and efficacy of the 2 surface-modified Pipeline iterations, Pipeline Vantage and Pipeline Flex with Shield Technology (PFS). MATERIALS AND
methodsConsecutive patients treated between 2017 and 2023 were retrospectively reviewed for aneurysm characteristics, procedural details, complications, and angiographic outcomes. The safety end point was the rate of procedural and postprocedural major neurologic events occurring during the hospital stay. The efficacy end point was the rate of complete occlusion at last follow-up.
resultsOne hundred forty-one patients underwent 112 Pipeline Vantage procedures and 32 PFS procedures for 147 aneurysms with a mean size of 8.0 (SD, 5.9) mm (11% ruptured, 16% posterior circulation, 18% nonsaccular morphology). All procedures were technically successful with a mean of 1.2 devices implanted. Balloon angioplasty was required in 20/144 (13.9%) procedures. Major neurologic adverse events occurred in 6/144 (4.2%) procedures (all ischemic stroke), resulting in death in 2 (1.4%) patients. There were no hemorrhagic complications. At a mean of 11 months, complete occlusion was achieved in 85/112 (75.9%) aneurysms, 15/112 (13.4%) had an entry remnant, and 12/112 (10.7%) had an aneurysm remnant.
conclusionsThe results demonstrate high feasibility, procedural safety, and efficacy of the surface-modified Pipeline flow diverters.