Evidence map›Paper›PMID 39120770›Full record

ArticleAnnals of biomedical engineering2025

Calibration of Aseptic Loosening Simulation for Coatings Osteoinductive Effect.

Sofia Baroni, Sara Oliviero, Antonino Amedeo La Mattina, Melania Maglio, Lucia Martini, Milena Fini, Marco Viceconti

Abstract read
In one paragraph

Article in Annals of biomedical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sofia BaroniDepartment of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Bologna, Italy. sofia.baroni2@unibo.it.ORCID http://orcid.org/0009-0009-6541-9914
Sara OlivieroDepartment of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Bologna, Italy.ORCID http://orcid.org/0000-0002-3111-2609
Antonino Amedeo La MattinaMedical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano1/10, 40136, Bologna, Italy.ORCID http://orcid.org/0000-0002-9927-2393
Melania MaglioSC Scienze e Tecnologie Chirurgiche, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.ORCID http://orcid.org/0000-0002-3778-4406
Lucia MartiniSC Scienze e Tecnologie Chirurgiche, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.ORCID http://orcid.org/0000-0001-5765-4839
Milena FiniScientific Direction, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.ORCID http://orcid.org/0000-0002-3732-3570
Marco VicecontiDepartment of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Bologna, Italy.ORCID http://orcid.org/0000-0002-2293-1530

Funding

Horizon 2020 Framework Programme 101016503
6 · The paper itself

Abstract

The risk of aseptic loosening in cementless hip stems can be reduced by improving osseointegration with osteoinductive coatings favoring long-term implant stability. Osseointegration is usually evaluated in vivo studies, which, however, do not reproduce the mechanically driven adaptation process. This study aims to develop an in silico model to predict implant osseointegration and the effect of induced micromotion on long-term stability, including a calibration of the material osteoinductivity with conventional in vivo studies. A Finite Element model of the tibia implanted with pins was generated, exploiting bone-to-implant contact measures of cylindrical titanium alloys implanted in rabbits' tibiae. The evolution of the contact status between bone and implant was modeled using a finite state machine, which updated the contact state at each iteration based on relative micromotion, shear and tensile stresses, and bone-to-implant distance. The model was calibrated with in vivo data by identifying the maximum bridgeable gap. Afterward, a push-out test was simulated to predict the axial load that caused the macroscopic mobilization of the pin. The bone-implant bridgeable gap ranged between 50 μm and 80 μm. Predicted push-out strength ranged from 19 N to 21 N (5.4 MPa-3.4 MPa) depending on final bone-to-implant contact. Push-out strength agrees with experimental measurements from a previous animal study (4 ± 1 MPa), carried out using the same implant material, coated, or uncoated. This method can partially replace in vivo studies and predict the long-term stability of cementless hip stems.

Indexed as

Coated Materials, BiocompatibleModels, BiologicalOsseointegrationProsthesis FailureTibiaAnimalsCalibrationComputer SimulationFinite Element AnalysisRabbitsTitaniumCoated Materials, BiocompatibleTitaniumBone-to-implant interfaceFinite element modelIn silico modelLong-term stabilityMicromotionOsseointegration

Identifiers

PMID39120770
PMCPMC11782331

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.