Evidence map›Paper›PMID 39119554›Full record

ReviewDigital health

Predicting obstructive sleep apnea hypopnea syndrome using three-dimensional optical devices: A systematic review.

Beibei Chen, Rongkai Cao, Danni Song, Piaopiao Qiu, Chongshan Liao, Yongming Li

Abstract readReview
In one paragraph

Review in Digital health. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Beibei ChenShanghai Engineering Research Center of Tooth Restoration and Regeneration & Tongji Research Institute of Stomatology & Department of Orthodontics, Stomatological Hospital and Dental School, Tongji University, Shanghai, China.
Rongkai CaoShanghai Engineering Research Center of Tooth Restoration and Regeneration & Tongji Research Institute of Stomatology & Department of Orthodontics, Stomatological Hospital and Dental School, Tongji University, Shanghai, China.
Danni SongShanghai Engineering Research Center of Tooth Restoration and Regeneration & Tongji Research Institute of Stomatology & Department of Orthodontics, Stomatological Hospital and Dental School, Tongji University, Shanghai, China.
Piaopiao QiuShanghai Engineering Research Center of Tooth Restoration and Regeneration & Tongji Research Institute of Stomatology & Department of Orthodontics, Stomatological Hospital and Dental School, Tongji University, Shanghai, China.
Chongshan LiaoShanghai Engineering Research Center of Tooth Restoration and Regeneration & Tongji Research Institute of Stomatology & Department of Orthodontics, Stomatological Hospital and Dental School, Tongji University, Shanghai, China.
Yongming LiShanghai Engineering Research Center of Tooth Restoration and Regeneration & Tongji Research Institute of Stomatology & Department of Orthodontics, Stomatological Hospital and Dental School, Tongji University, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: As a global health concern, the diagnosis of obstructive sleep apnea hypopnea syndrome (OSAHS), characterized by partial reductions and complete pauses in ventilation, has garnered significant scientific and public attention. With the advancement of digital technology, the utilization of three-dimensional (3D) optical devices demonstrates unparalleled potential in diagnosing OSAHS. This study aimed to review the current literature to assess the accuracy of 3D optical devices in identifying the prevalence and severity of OSAHS. Methods: A systematic literature search was conducted in the Web of Science, Scopus, PubMed/MEDLINE, and Cochrane Library databases for English studies published up to April 2024. Peer-reviewed researches assessing the diagnostic utility of 3D optical devices for OSAHS were included. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) guideline was employed to appraise the risk of bias. Results: The search yielded 3216 results, with 10 articles meeting the inclusion criteria for this study. Selected studies utilized structured light scanners, stereophotogrammetry, and red, green, blue-depth (RGB-D) cameras. Stereophotogrammetry-based 3D optical devices exhibited promising potential in OSAHS prediction. Conclusions: The utilization of 3D optical devices holds considerable promise for OSAHS diagnosis, offering potential improvements in accuracy, cost reduction, and time efficiency. However, further clinical data are essential to assist clinicians in the early detection of OSAHS using 3D optical devices.

Indexed as

accuracyObstructive sleep apnea hypopnea syndromepredictionthree-dimensional optical device

Identifiers

PMID39119554
PMCPMC11307370

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.