Evidence map›Paper›PMID 39119048›Full record

ArticleJournal of experimental orthopaedics2024

Radial head arthroplasty diameter impact on elbow kinematics evaluated by dynamic radiostereometric analysis.

Johanne F Teilmann, Emil T Petersen, Theis M Thillemann, Chalotte K Hemmingsen, Josephine O Kipp, Maiken Stilling

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Johanne F TeilmannAutoRSA Research Group, Orthopedic Research Unit Aarhus University Hospital Aarhus Denmark.ORCID https://orcid.org/0009-0007-5918-3875
Emil T PetersenAutoRSA Research Group, Orthopedic Research Unit Aarhus University Hospital Aarhus Denmark.
Theis M ThillemannDepartment of Clinical Medicine Aarhus University Aarhus Denmark.
Chalotte K HemmingsenAutoRSA Research Group, Orthopedic Research Unit Aarhus University Hospital Aarhus Denmark.
Josephine O KippAutoRSA Research Group, Orthopedic Research Unit Aarhus University Hospital Aarhus Denmark.
Maiken StillingAutoRSA Research Group, Orthopedic Research Unit Aarhus University Hospital Aarhus Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Radial head arthroplasty (RHA) reestablishes elbow stability after complex radial head fracture, but complication rates are high, possibly due to inappropriate implant sizing. Knowledge of impact of radial head implant diameter on elbow kinematics is limited and warranted. This study evaluated elbow kinematics of different radial head implant diameters after RHA using dynamic radiostereometric analysis (dRSA). Methods: Eight human donor arms were examined with dRSA during elbow flexion with the forearm in unloaded neutral position, and in supinated- and pronated position without and with 10N either varus or valgus load, respectively. Elbow kinematics were examined before and after RHA with head diameters of anatomical size, -2 mm (undersized), and +2 mm (oversized). The ligaments were kept intact by use of step-cut humerus osteotomy for repeated RHA exchange. Bone models were obtained from CT, and by AutoRSA software bone models were matched with dRSA recordings. The elbow kinematics were described using anatomical coordinate systems. Results: Compared to the native radial head during elbow flexion, the anatomical sized RHA shifted 2.0 mm in ulnar direction during unloaded pronated forearm position. The undersized RHA shifted 1.5 mm in posterior direction and 2.1 mm in ulnar direction during unloaded pronated forearm position and increased the varus angle by 2.4° during supinated loaded forearm position. The oversized RHA shifted 1.6 mm in radial direction during loaded supinated forearm position. Conclusions: The anatomically sized RHA should be preferred as it maintained native elbow kinematics the best. The kinematic changes with oversized and undersized RHA diameters were small, suggesting forgiveness for the RHA diameter size. Level of Evidence: Level III.

Indexed as

elbowkinematicsradial head arthroplastyradial head diameterradiostereometry

Identifiers

PMID39119048
PMCPMC11306918

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked