Evidence map›Paper›PMID 39118958›Full record

ArticleAnnals of translational medicine2024

The effect of osteotomy depth and hinge axis orientation on biplanar surgical accuracy in medial opening-wedge high tibial osteotomy-a deeper understanding by 3D simulations.

Wouter Van Genechten, Annemieke Van Haver, Jozef Michielsen, Steven Claes, Peter Verdonk

Abstract read
In one paragraph

Article in Annals of translational medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Wouter Van GenechtenDepartment of Orthopaedic Surgery, University Hospital Antwerp, Antwerp, Belgium.
Annemieke Van HaverMore Institute, Orthopedic Research Department, AZ Monica Hospital, Antwerp, Belgium.
Jozef MichielsenDepartment of Orthopaedic Surgery, University Hospital Antwerp, Antwerp, Belgium.
Steven ClaesOrthopedic Department, AZ Herentals Hospital, Antwerp, Belgium.
Peter VerdonkDepartment of Orthopaedic Surgery, University Hospital Antwerp, Antwerp, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Not all surgical osteotomy steps have been properly investigated for their potential impact on surgical accuracy. The main study objective was to investigate the osteotomy parameters that have respectively major and minor impact on coronal and sagittal bony accuracy in medial opening-wedge high tibial osteotomy (MOWHTO). Methods: Three tibias from an existing 3D MOWHTO osteotomy database were chronologically selected based on segmentation quality, tibial plateau size and the presence of tibial varus. The study consisted of three parts: (I) translating the hinge axis in the coronal plane and switching the osteotomy starting point (30-40 mm) and depth, (II) the hinge axis was rotated stepwise by 10° to perform five simulations, (III) the hinge axis was rotated in the axial plane stepwise by 10° towards anterolateral to perform four simulations (0°, +10°, +20°, +30°). The medial proximal tibial angle (MPTA) and lateral tibial slope were the primary outcomes. Simulations were performed with 5, 10 and 15 mm gap distraction. Results: In the coronal plane, maximum difference in osteotomy depth was 10 mm which represented an MPTA difference of 0.8°-1.1° in 10 mm gap distraction and 1.2°-2.0° in 15 mm gap distraction. Tibial slope remained unchanged. Rotating the hinge axis in the sagittal plane delivered minor changes on both MPTA (<0.5°) and tibial slope (<1.5°) at 10 mm gap distraction. Per 10° of axial rotation of the hinge axis towards anterolateral, the tibial slope increased by 1.0°-1.3° in 10 mm gap distraction while the MPTA remains nearly unchanged. Conclusions: The study showed that the medio-lateral osteotomy length is the main parameter for obtaining bony accuracy in the coronal plane and maintaining a strict perpendicular axial hinge axis position is crucial in preserving the native tibial slope. Correct axial alignment of the hinge axis can be obtained by creating an equal osteotomy depth of the anterior and posterior tibial cortices in the lateral metaphyseal area.

Indexed as

3D simulationaccuracyHigh tibial osteotomyhinge axisposterior tibial slope

Identifiers

PMID39118958
PMCPMC11304427

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.