ArticleAnnals of translational medicine2024
The effect of osteotomy depth and hinge axis orientation on biplanar surgical accuracy in medial opening-wedge high tibial osteotomy-a deeper understanding by 3D simulations.
Article in Annals of translational medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Not all surgical osteotomy steps have been properly investigated for their potential impact on surgical accuracy. The main study objective was to investigate the osteotomy parameters that have respectively major and minor impact on coronal and sagittal bony accuracy in medial opening-wedge high tibial osteotomy (MOWHTO). Methods: Three tibias from an existing 3D MOWHTO osteotomy database were chronologically selected based on segmentation quality, tibial plateau size and the presence of tibial varus. The study consisted of three parts: (I) translating the hinge axis in the coronal plane and switching the osteotomy starting point (30-40 mm) and depth, (II) the hinge axis was rotated stepwise by 10° to perform five simulations, (III) the hinge axis was rotated in the axial plane stepwise by 10° towards anterolateral to perform four simulations (0°, +10°, +20°, +30°). The medial proximal tibial angle (MPTA) and lateral tibial slope were the primary outcomes. Simulations were performed with 5, 10 and 15 mm gap distraction. Results: In the coronal plane, maximum difference in osteotomy depth was 10 mm which represented an MPTA difference of 0.8°-1.1° in 10 mm gap distraction and 1.2°-2.0° in 15 mm gap distraction. Tibial slope remained unchanged. Rotating the hinge axis in the sagittal plane delivered minor changes on both MPTA (<0.5°) and tibial slope (<1.5°) at 10 mm gap distraction. Per 10° of axial rotation of the hinge axis towards anterolateral, the tibial slope increased by 1.0°-1.3° in 10 mm gap distraction while the MPTA remains nearly unchanged. Conclusions: The study showed that the medio-lateral osteotomy length is the main parameter for obtaining bony accuracy in the coronal plane and maintaining a strict perpendicular axial hinge axis position is crucial in preserving the native tibial slope. Correct axial alignment of the hinge axis can be obtained by creating an equal osteotomy depth of the anterior and posterior tibial cortices in the lateral metaphyseal area.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.