ArticleStatistical methods in medical research2024
Estimation and inference on the partial volume under the receiver operating characteristic surface.
Article in Statistical methods in medical research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
measures of biomarker accuracy that employ the receiver operating characteristic surface have been proposed for biomarkers that classify patients into one of three groups: healthy, benign, or aggressive disease. The volume under the receiver operating characteristic surface summarizes the overall discriminatory ability of a biomarker in such configurations, but includes cutoffs associated with clinically irrelevant true classification rates. Due to the lethal nature of pancreatic cancer, cutoffs associated with a low true classification rate for identifying patients with pancreatic cancer may be undesirable and not appropriate for use in a clinical setting. In this project, we study the properties of a more focused criterion, the partial volume under the receiver operating characteristic surface, that summarizes the diagnostic accuracy of a marker in the three-class setting for regions restricted to only those of clinical interest. We propose methods for estimation and inference on the partial volume under the receiver operating characteristic surface under parametric and non-parametric frameworks and apply these methods to the evaluation of potential biomarkers for the diagnosis of pancreatic cancer.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.