Evidence map›Paper›PMID 39117362›Full record

ArticleBMJ open ophthalmology2024

IOL decentration sensitivity according to spatial frequencies.

Stefan Pieh, Cornelia Artmayr, Daniel Schartmüller, Katharina Kriechbaum

Abstract read
In one paragraph

Article in BMJ open ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Trial
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Stefan PiehDepartment of Ophthalmology & Optometry, Medical University of Vienna, Vienna, Austria stefan.pieh@meduniwien.ac.at.ORCID 0000-0001-5594-7232
Cornelia ArtmayrDepartment of Ophthalmology & Optometry, Medical University of Vienna, Vienna, Austria.
Daniel SchartmüllerDepartment of Ophthalmology & Optometry, Medical University of Vienna, Vienna, Austria.ORCID 0000-0002-5669-3606
Katharina KriechbaumDepartment of Ophthalmology & Optometry, Medical University of Vienna, Vienna, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND/

aimsInvestigation of the decentration sensitivity of monofocal intraocular implants with a focus on different aberration corrections depending on different spatial frequencies.

methodsUsing an optical bench, the decentration sensitivities of an intraocular lens (IOL) with a high spherical aberration correction of -0.27 µm (ZCB00 Johnson & Johnson), an IOL with an aberration correction of -0.20 µm (Primus HD OphthalmoPro) and an IOL with an aberration neutral design (CT Asphina 409MP Carl Zeiss Meditec) were evaluated for Strehl ratio values and for 25, 50 and 100 lp/mm. Two different corneas with +0.13 µm and +0.28 µm were used. The lenses were tested in the best centration and up to a decentration of 0.5 mm.

resultsDecentration sensitivity affects high spatial frequencies more than lower ones. The possible decentration sensitivity is determined by the amount of spherical aberration of the cornea. The effective decentration sensitivity is determined by the extent to which these spherical aberrations are compensated. If these are not compensated, there is hardly any decentration sensitivity.

conclusionHigh spatial frequencies are more affected by decentration sensitivity. The decentration sensitivity of an IOL is determined by the extent to which the spherical aberration of the cornea is corrected.

Indexed as

Lenses, IntraocularArtificial Lens Implant MigrationCorneaHumansLens Implantation, IntraocularProsthesis DesignCataractCorneaExperimental & laboratoryOptics and Refraction

Identifiers

PMID39117362
PMCPMC11409404

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.