ArticleIEEE transactions on bio-medical engineering2025
MRI Retrospective Respiratory Gating and Cardiac Sensing by CW Doppler Radar: A Feasibility Study.
Article in IEEE transactions on bio-medical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- 4D Flow MRI at 0.6 T-Self-Gating Versus Camera-Based Respiratory Binning.Bioengineering (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
objectiveThis study investigates the feasibility of non-contact retrospective respiratory gating and cardiac sensing using continuous wave Doppler radar deployed in an MRI system. The proposed technique can complement existing sensors which are difficult to apply for certain patient populations.
methodsWe leverage a software-defined radio for continuous wave radar at 2.4 GHz to detect in-vivo respiratory and cardiac time-scrolled signals. In-bore radar signal demodulation is verified with full electromagnetic simulations, and its functionality is validated on a test bench and within the MR bore with four normal subjects. Radar sensing was compared against well-known references: electrocardiography on a test bench, system bellows, and pulsed plethysmography sensors within the MRI bore.
resultsThe feasibility of non-contact cardiac rate sensing, dynamic breathing sequence synchronization, and in-bore motion correction for retrospective respiratory gating applications was demonstrated. Optimal radar front-end system arrangement, along with spectral isolation and narrow bandwidth of operation, enable MRI-compatible and interference-free motion sensing. The signal-to-noise-ratio degradation by the radar integration was within 4.5% on phantom images.
conclusionWe confirmed that in-bore retrospective motion correction using CW Doppler radar is feasible without MRI system constraints. SIGNIFICANCE: Non-contact motion correction sensing in MRI may provide better patient handling and throughput by complementing existing system sensors and motion correction algorithms.