ArticlePlastic and reconstructive surgery. Global open2024
Simulating the Morphological Changes of Facial Deformities after Using 3D-printed Polyether Ether Ketone Facial Implants.
Article in Plastic and reconstructive surgery. Global open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Complications After Patient-specific Implants for Facial Contouring and Augmentation: A Systematic Review and Meta-analysis.Plastic and reconstructive surgery. Global open · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Patient-specific implants (PSIs) have been presented as an effective solution for diseases that require reconstruction. PSIs are designed to precisely fit anatomical defects or deformities in terms of shape and size. In addition to the possibility of predicting the results of surgery regarding soft tissue changes. Methods: A research sample consisting of 10 patients with facial deformities underwent maxillofacial reconstructive surgery between 2020 and 2021 in the Tishreen University Hospital, Syria. All patients underwent computed tomography scans; then, the design of the required facial implant was carried out, and the three-dimensional soft tissues were reconstructed using the ExoCad 3.0 program based on the computed tomography. The final form of the facial implant was printed from polyether ether ketone, and then surgical work was performed. The patients were followed up after 6 months. Then, a comparison was made between the virtual design and the real result. Results: The absolute difference between the expected soft tissue changes result and the actual result did not exceed three-tenths for all patients, and only two of 10 patients had measurements higher than 20%. Conclusions: This technique can be relied upon with the placement of implants to predict the outcome of the surgical procedure in terms of morphological changes in the facial soft tissues covering PSI polyether ether ketone. Therefore, it is possible to make a virtual design based on the cosmetic requirements of the patient.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.