ArticleBMC oral health2024
Tissue surface adaptation and retention of digital obturator after one year of use.
Article in BMC oral health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Patient satisfaction with conventional versus fully digital obturators fabricated with 3D printing: a randomized crossover trial.BMC oral health · 2025Trial
- Evaluation of Non-dental open source software in comparison to dental software in construction of digitally designed partial dentures frameworks.Scientific reports · 2025Article
- Fully Digital Fabrication of Maxillary Obturator by Enhancing Rough Scan Data With Blender®: A Case Report.Cureus · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundEffect of aging on tissue adaptability and retention of digital obturator is still under investigation.
methodsA maxillary Armany (class I) epoxy reference model was scanned to fabricate digital obturator fabricated from milled Co-Cr framework and 3D printed bulb. A color map of the scanned reference and digital obturator was made using Geomagic software to evaluate the accuracy of fit before and after cyclic loading using ROBOTA chewing simulator at 37,500, 75,000 and 150,000 cycles to simulate clinically 3-, 6- and 12-months chewing condition. Insertion-removal condition simulating the placement and removal of the obturator was done using repeated 360, 720 and 1440 cycles and retention was evaluated before and after the repeated cycles. Data were collected, tabulated and statistically analyzed using Statistical Package for Social Sciences (IBM SPSS Statistics 26). Student t-test and multi variable ANOVA test were used to detect significance. P-value < 0.05 was considered significant difference.
resultsFor retention test: There was a significant difference between baseline and 3, 6 and12 months. For the tissue surface adaptation test: There was significant difference at all measured areas (P-value < 0.05) before and after application of load.
conclusiondigitally designed and fabricated obturator was highly retentive and has excellent tissue surface adaptation upon fabrication, After application of load; reduction of retention and lack of tissue adaptation were resulted. THE CLINICAL IMPLICATION: of this manuscript is that digital obturator can be used successfully with the shortcomings of loosening retention and adaptation afterwhile. So, clinical trials should investigate the clinical acceptance of these shortcomings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.