ArticleJournal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale
Reducing Unnecessary Instruments in Tonsil Hemorrhage Trays at a Canadian Tertiary Care Center: A Quality Improvement Project.
Article in Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Pooled it
- Applying Abstract Text Mining as a Complement to PRISMA in Reviewing the Scope of Healthcare's Circular Economy Comment on "A Review of the Applicability of Current Green Practices in Healthcare Facilities".International journal of health policy and management · 2026Article
- Tray Rationalization in Pediatric Day Surgery: A Sustainable Quality Improvement Project.World journal of surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIn the emergency department (ED), there are pre-assembled tonsillar hemorrhage trays for management of post-tonsillectomy hemorrhage and peritonsillar abscess. After use, the tray is sent to the medical device reprocessing (MDR) department for decontamination, sterilization, and re-organization, all at a significant cost to the hospital and environment.
objectiveThe goal of this project was to reduce unnecessary instruments on the tonsil hemorrhage tray by 30% by 1 year and report on the associated cost and carbon dioxide (CO
methodsThis quality improvement project was framed according to the Institute for Healthcare Improvement's Model for Improvement. ED and Otolaryngology-Head & Neck Surgery staff and residents were surveyed to determine which instruments on the tonsil hemorrhage trays were used regularly. Based on results, a new tray was developed and compared to the old tray using MDR data and existing CO
resultsTray optimization resulted in a total cost reduction from $1092.63 to $330.21 per tray per year, decreased processing time from 12 to 6-8 minutes per tray, and decreased CO
conclusionHealthcare costs and environmental sustainability are collective responsibilities. Surgical and procedure tray optimization is a simple, effective, and scalable form of eco-action.