Evidence map›Paper›PMID 39109740›Full record

ArticleArquivos brasileiros de oftalmologia2024

Comparison of safety and effectiveness of micropulse transscleral cyclophotocoagulation and "slow cook" diode laser transscleral cyclophotocoagulation in patients with refractory open-angle glaucoma.

Heloisa Helena Abil Russ, Regina Cele Silveira Seixas, Heloísa Andrade Maestrini, Marcos Balbino, Thatiana Almeida Pereira Fernandes, Núbia Vanessa Dos Anjos Lima, Nara Lídia Vieira Lopes, Taurino Dos Santos Rodrigues Neto

Abstract readComparative Study
In one paragraph

Article in Arquivos brasileiros de oftalmologia, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Heloisa Helena Abil RussHR Oftalmologia, Curitiba, PR, Brazil.ORCID 0000-0001-9738-6912
Regina Cele Silveira SeixasHCLOE Clínica de Oftalmologia Especializada, São Paulo, SP, Brazil.ORCID 0000-0001-5183-1216
Heloísa Andrade MaestriniOculare Hospital de Oftalmologia, Belo Horizonte, MG, Brazil.ORCID 0000-0001-5189-783X
Marcos BalbinoCentro Universitário São Camilo, São Paulo, SP, Brazil.ORCID 0000-0001-7142-5055
Thatiana Almeida Pereira FernandesOculare Hospital de Oftalmologia, Belo Horizonte, MG, Brazil.ORCID 0000-0002-0264-8105
Núbia Vanessa Dos Anjos LimaVisionOne- Hospital de Olhos CBV, Brasilia, DF, Brazil.ORCID 0000-0003-3693-1934
Nara Lídia Vieira LopesVisionOne- Hospital de Olhos CBV, Brasilia, DF, Brazil.ORCID 0000-0002-9453-6767
Taurino Dos Santos Rodrigues NetoDepartment of Ophthalmology, Universidade de São Paulo, São Paulo, SP, Brazil.ORCID 0000-0002-9182-1044

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to compare the safety and effectiveness of intraocular pressure reduction between micropulse transscleral cyclophotocoagulation and "slow cook" transscleral cyclophotocoagulation in patients with refractory primary open-angle glaucoma.

methodsWe included patients with primary open angle glaucoma with at least 12 months of follow-up. We collected and analyzed data on the preoperative characteristics and postoperative outcomes. The primary outcomes were a reduction of ≥20% of the baseline value (criterion A) and/or intraocular pressure between 6 and 21 mmHg (criterion B).

resultsWe included 128 eyes with primary open-angle glaucoma. The preoperative mean intraocular pressure was 25.53 ± 6.40 and 35.02 ± 12.57 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean intraocular pressure was reduced significantly to 14.33 ± 3.40 and 15.37 ± 5.85 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups at the last follow-up, respectively (p=0.110). The mean intraocular pressure reduction at 12 months was 11.20 ± 11.46 and 19.65 ± 13.22 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The median preoperative logMAR visual acuity was 0.52 ± 0.69 and 1.75 ± 1.04 in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean visual acuity variation was -0.10 ± 0.35 and -0.074 ± 0.16 in the micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p=0.510). Preoperatively, the mean eye drops were 3.44 ± 1.38 and 2.89 ± 0.68 drugs in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p=0.017), but those were 2.06 ± 1.42 and 1.02 ± 1.46 at the end of the study in the "slow cook" and micropulse transscleral cyclophotocoagulation groups, respectively (p<0.001). The success of criterion A was not significant between both groups. Compared with 11 eyes (17.74%) in the "slow cook" transscleral cyclophotocoagulation group, 19 eyes (28.78%) in the micropulse transscleral cyclophotocoagulation group showed complete success (p=0.171). For criterion B, 28 (42.42%) and 2 eyes (3.22%) showed complete success after micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p<0.001).

conclusionBoth techniques reduced intraocular pressure effectively.

Indexed as

Glaucoma, Open-AngleIntraocular PressureLaser CoagulationLasers, SemiconductorScleraAdultAgedCiliary BodyFemaleFollow-Up StudiesHumansMaleMiddle AgedPostoperative PeriodTime FactorsTreatment Outcome

Identifiers

PMID39109740
PMCPMC12588612

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.