Evidence map›Paper›PMID 39108302›Full record

ArticlePNAS nexus2024

SPOT-RASTR-A cryo-EM specimen preparation technique that overcomes problems with preferred orientation and the air/water interface.

Behrouz G Esfahani, Peter S Randolph, Ruizhi Peng, Timothy Grant, M Elizabeth Stroupe, Scott M Stagg

Abstract read
In one paragraph

Article in PNAS nexus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Behrouz G EsfahaniInstitute of Molecular Biophysics, Florida State University, 91 Chieftan Way, Tallahassee, FL 32306, USA.ORCID https://orcid.org/0000-0001-5954-8933
Peter S RandolphInstitute of Molecular Biophysics, Florida State University, 91 Chieftan Way, Tallahassee, FL 32306, USA.
Ruizhi PengInstitute of Molecular Biophysics, Florida State University, 91 Chieftan Way, Tallahassee, FL 32306, USA.ORCID https://orcid.org/0000-0001-6057-8961
Timothy GrantDepartment of Biochemistry, University of Wisconsin-Madison, 433 Babcock Drive, Madison, WI 53706, USA.ORCID https://orcid.org/0000-0002-4855-8703
M Elizabeth StroupeInstitute of Molecular Biophysics, Florida State University, 91 Chieftan Way, Tallahassee, FL 32306, USA.ORCID https://orcid.org/0000-0002-4393-1951
Scott M StaggInstitute of Molecular Biophysics, Florida State University, 91 Chieftan Way, Tallahassee, FL 32306, USA.ORCID https://orcid.org/0000-0001-8855-4152

Funding

cryoEM Studies on MuscleR35GM139616 · NIGMS · FLORIDA STATE UNIVERSITY · PI KENNETH ALLEN TAYLOR · 2021 to 2026
$2.9M
NIGMS NIH HHS R35 GM139616
6 · The paper itself

Abstract

In cryogenic electron microscopy (cryo-EM), specimen preparation remains a bottleneck despite recent advancements. Classical plunge freezing methods often result in issues like aggregation and preferred orientations at the air/water interface. Many alternative methods have been proposed, but there remains a lack a universal solution, and multiple techniques are often required for challenging samples. Here, we demonstrate the use of lipid nanotubes with nickel NTA headgroups as a platform for cryo-EM sample preparation. His-tagged specimens of interest are added to the tubules, and they can be frozen by conventional plunge freezing. We show that the nanotubes protect samples from the air/water interface and promote a wider range of orientations. The reconstruction of average subtracted tubular regions (RASTR) method allows for the removal of the nanotubule signal from the cryo-EM images resulting in isolated images of specimens of interest. Testing with β-galactosidase validates the method's ability to capture particles at lower concentrations, overcome preferred orientations, and achieve near-atomic resolution reconstructions. Since the nanotubules can be identified and targeted automatically at low magnification, the method enables fully automated data collection. Furthermore, the particles on the tubes can be automatically identified and centered using 2D classification enabling particle picking without requiring prior information. Altogether, our approach that we call specimen preparation on a tube RASTR holds promise for overcoming air-water interface and preferred orientation challenges and offers the potential for fully automated cryo-EM data collection and structure determination.

Indexed as

automationresolution anisotropyvitreous ice

Identifiers

PMID39108302
PMCPMC11303004

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.