Evidence map›Paper›PMID 39107920›Full record

ArticleInternational wound journal2024

Influence of the biomechanical evaluation of rupture using two shapes of same intramedullary implant after proximal interphalangeal joint arthrodesis to correct the claw/hammer pathology: A finite element study.

Javier Bayod-López, Ricardo Becerro-de-Bengoa-Vallejo, Juan Carlos Prados-Frutos, Marta Losa-Iglesias, Daniel López-López, María Prados-Privado

Abstract readCase Reports
In one paragraph

Article in International wound journal, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Javier Bayod-LópezApplied Mechanics and Bioengineering Group (AMB), Aragon Institute of Engineering Research (I3A), Centro de Investigación Biomédica en Red CIBER-BBN, Spain, Universidad de Zaragoza, Zaragoza, Spain.
Ricardo Becerro-de-Bengoa-VallejoFacultad de Enfermería, Fisioterapia y Podología, Universidad Complutense de Madrid, Madrid, Spain.
Juan Carlos Prados-FrutosDepartment of Medical Specialties and Public Health, IDIBO Group (High Performance Group in Research and Development of Biomaterials in Dentistry), Rey Juan Carlos University, Madrid, Spain.
Marta Losa-IglesiasFacultad de CC de la Salud, Universidad Rey Juan Carlos, Madrid, Spain.
Daniel López-LópezResearch, Health and Podiatry Group, Department of Health Sciences, Faculty of Nursing and Podiatry, Industrial Campus of Ferrol, Universidade da Coruña, Ferrol, Spain.ORCID https://orcid.org/0000-0002-9818-6290
María Prados-PrivadoDepartment Continuum Mechanics and Structural Analysis, Higher Polytechnic School,, Carlos III University, Leganes, Madrid, Spain.

Funding

Economy and Competitiveness Ministry DPI2013-44987-RFunding for open access charge: Universidade da Coruña/CISUG.
6 · The paper itself

Abstract

We used finite element analysis to study the mechanical stress distribution of a new intramedullary implant used for proximal interphalangeal joint (PIPJ) arthrodesis (PIPJA) to surgically correct the claw-hammer toe deformity that affects 20% of the population. After geometric reconstruction of the foot skeleton from claw toe images of a 36-year-old male patient, two implants were positioned, in the virtual model, one neutral implant (NI) and another one 10° angled (10°AI) within the PIPJ of the second through fourth HT during the toe-off phase of gait and results were compared to those derived for the non-surgical foot (NSF). A PIPJA was performed on the second toe using a NI reduced tensile stress at the proximal phalanx (PP) (45.83 MPa) compared to the NSF (59.44 MPa; p < 0.001). When using the 10°AI, the tensile stress was much higher at PP and middle phalanges (MP) of the same toe, measuring 147.58 and 160.58 MPa, respectively, versus 59.44 and 74.95 MPa at corresponding joints in the NSF (all p < 0.001). Similar results were found for compressive stresses. The NI reduced compressive stress at the second PP (-65.12 MPa) compared to the NSF (-113.23 MPa) and the 10°AI (-142 MPa) (all p < 0.001). The von Mises stresses within the implant were also significantly lower when using NI versus 10°AI (p < 0.001). Therefore, we do not recommend performing a PIPJA using the 10°AI due to the increase in stress concentration primarily at the second PP and MP, which could promote implant breakage.

Indexed as

ArthrodesisFinite Element AnalysisHammer Toe SyndromeToe JointAdultBiomechanical PhenomenaHumansMalefootfoot deformitiesfoot diseasesmusculoskeletal diseases

Identifiers

PMID39107920
PMCPMC11303262

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.