Evidence map›Paper›PMID 39107444›Full record

ArticleScientific reports2024

Early monitoring of inlay wear after total knee arthroplasty on plain radiographs using model-based wear measurement.

Crystal Kayaro Emonde, Christof Hurschler, André Breuer, Max-Enno Eggers, Marcel Wichmann, Max Ettinger, Berend Denkena

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Crystal Kayaro EmondeLaboratory for Biomechanics and Biomaterials, Hannover Medical School, Department of Orthopaedic Surgery, DIAKOVERE Annastift, Anna Von Borries Str. 1-7, 30625, Hannover, Germany. emonde.crystal@mh-hannover.de.ORCID 0000-0001-6557-3756
Christof HurschlerLaboratory for Biomechanics and Biomaterials, Hannover Medical School, Department of Orthopaedic Surgery, DIAKOVERE Annastift, Anna Von Borries Str. 1-7, 30625, Hannover, Germany.
André BreuerLaboratory for Biomechanics and Biomaterials, Hannover Medical School, Department of Orthopaedic Surgery, DIAKOVERE Annastift, Anna Von Borries Str. 1-7, 30625, Hannover, Germany.
Max-Enno EggersInstitute of Production Engineering and Machine Tools, Leibniz University Hannover, An Der Universität 2, Garbsen, 30823, Hannover, Germany.
Marcel WichmannInstitute of Production Engineering and Machine Tools, Leibniz University Hannover, An Der Universität 2, Garbsen, 30823, Hannover, Germany.
Max EttingerDepartment of Orthopaedic Surgery, Pius-Hospital Oldenburg, University Clinic for Orthopaedics and Trauma Surgery, Georgstraße 12, 26121, Oldenburg, Germany.
Berend DenkenaInstitute of Production Engineering and Machine Tools, Leibniz University Hannover, An Der Universität 2, Garbsen, 30823, Hannover, Germany.

Funding

Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) Project-ID 426335750
6 · The paper itself

Abstract

Wear of the ultra-high molecular-weight polyethylene (UHMWPE) component in total knee arthroplasty contributes to implant failure. It is often detected late, when patients experience pain or instability. Early monitoring could enable timely intervention, preventing implant failure and joint degeneration. This study investigates the accuracy and precision (repeatability) of model-based wear measurement (MBWM), a novel technique that can estimate inlay thickness and wear radiographically. Six inlays were milled from non-crosslinked UHMWPE and imaged via X-ray in anteroposterior view at flexion angles 0°, 30°, and 60° on a phantom knee model. MBWM measurements were compared with reference values from a coordinate measurement machine. Three inlays were subjected to accelerated wear generation and similarly evaluated. MBWM estimated inlay thickness with medial and lateral accuracies of 0.13 ± 0.09 and 0.14 ± 0.09 mm, respectively, and linear wear with an accuracy of 0.07 ± 0.06 mm. Thickness measurements revealed significant lateral differences at 0° and 30° (0.22 ± 0.08 mm vs. 0.06 ± 0.06 mm, respectively; t-test, p = 0.0002). Precision was high, with average medial and lateral differences of - 0.01 ± 0.04 mm between double experiments. MBWM using plain radiographs presents a practical and promising approach for the clinical detection of implant wear.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisProsthesis FailureHumansKnee JointMaterials TestingPolyethylenesRadiographyPolyethylenesultra-high molecular weight polyethyleneInlay wearIn-vivo wearMinimum thicknessModel-basedPolyethylene wearStandard radiograph

Identifiers

PMID39107444
PMCPMC11303532

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.