Evidence map›Paper›PMID 39106263›Full record

ArticlePloS one2024

Diagnosis with Metagenomic Next-Generation Sequencing (mNGS) technology and real-time PCR for SARS-CoV-2 Omicron detection using various nasopharyngeal swabs in SARS-CoV-2 Omicron.

Sujuan Li, Yuanhang Zhang, Pengcheng Tong, Wei Yang

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Sujuan LiDepartment of Clinical Laboratory, Hangzhou Traditional Chinese Medicine Hospital Affiliated to Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China.ORCID 0000-0002-6587-8661
Yuanhang ZhangDepartment of Clinical Laboratory, Hangzhou Traditional Chinese Medicine Hospital Affiliated to Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China.
Pengcheng TongDepartment of Clinical Laboratory, Hangzhou Traditional Chinese Medicine Hospital Affiliated to Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China.
Wei YangDepartment of Clinical Laboratory, Hangzhou Traditional Chinese Medicine Hospital Affiliated to Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe SARS-CoV-2 Omicron variant, with the main subtypes BA.5.2 and BF.7 in China, led to off-target effects on the S and N genes from December 1, 2022, to January 31, 2023. The kits used for studying and developing these agents were not adequately and independently evaluated. It is important to verify the performance of commercial Real-Time quantitative PCR (RT-qPCR) tests.

objectiveWe conducted a clinical evaluation of two Real Time SARS-CoV-2 Omicron assays to verify their performance using various detection reagents and clinical specimens.

methodsWe performed clinical evaluations of two existing Chinese SARS-CoV-2 Omicron RT-qPCR kits 2019-nCoV nucleic acid diagnostic kits (Fosun Biotechnology, National instrument registration 20203400299, Shanghai, China) and COVID-19 nucleic acid detection kits (eDiagnosis Biomedicine, National instrument registration 20203400212, Wuhan, China) and using BSD (Bondson) (Guangzhou Bondson Biotechnology Co. Ltd, batch number 2022101), quality controls provided by the inspection center and a large number of clinically confirmed specimens.

resultsThe concordance rates for the Fosun and eDiagnosis kits were 95% and 100%, respectively. The detection limit for the Fosun and eDiagnosis kits was verified to be 300 copies/mL and 500 copies/mL. The Fosun assay exhibited the largest coefficient of variation (CV) for ORF1ab and N gene at the detection limit concentration (4.80%, 3.49%), whereas eDiagnosis showed a smaller CV (0.93%, 1.10%). In the reference product from the Hangzhou Clinical Laboratory Center test, it was found that Fosun had the lowest sensitivity of 93.47% and a specificity of 100%, while eDiagnosis exhibited 100% for both sensitivity and specificity. The lowest single target gene detection rate of Fosun reagents was 68.7% for the ORF1ab gene and 87.5% for the N gene, while eDiagnosis detection rate was 100%. Among the clinical group S specimens, the missed detection rate of the Fosun reagent was 10.9%, which was higher than the 3.9% of eDiagnosis. However, there was no significant difference in the clinical diagnostic efficiency of the two reagents.

conclusionsThe ORF1ab and N assays of SARS-CoV-2 Omicron on the eDiagnosis platform yielded higher values compared to those on the Fosun platform. Consequently, the eDiagnosis kit has also been used as standard detection reagents. Considering that the Fosun reagent has a relatively low detection limit and targets three single genes, it is more advantageous as a confirmatory reagent for the new museum.

Indexed as

COVID-19High-Throughput Nucleotide SequencingReal-Time Polymerase Chain ReactionSARS-CoV-2ChinaCOVID-19 Nucleic Acid TestingHumansMetagenomicsNasopharynxReagent Kits, DiagnosticRNA, ViralSensitivity and SpecificityReagent Kits, DiagnosticRNA, Viral

Identifiers

PMID39106263
PMCPMC11302915

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.