Evidence map›Paper›PMID 39105300›Full record

ArticleMaterials horizons2024

Encapsulated stretchable amphibious strain sensors.

Shuang Wu, Doyun Kim, Xiaoqi Tang, Martin W King, Yong Zhu

Abstract read
In one paragraph

Article in Materials horizons, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Thermally Actuated Soft Robotics.Advanced materials (Deerfield Beach, Fla.) · 2025
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Shuang WuDepartment of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA. yzhu7@ncsu.edu.ORCID http://orcid.org/0000-0003-2579-9309
Doyun KimDepartment of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA. yzhu7@ncsu.edu.
Xiaoqi TangWilson College of Textiles, North Carolina State University, Raleigh, NC 27695, USA.
Martin W KingWilson College of Textiles, North Carolina State University, Raleigh, NC 27695, USA.
Yong ZhuDepartment of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695, USA. yzhu7@ncsu.edu.ORCID http://orcid.org/0000-0002-3862-5757

Funding

SCH: A personalized wearable rehabilitation sensing system for stroke survivorsR01HD108473 · NICHD · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI BARATTA, JOHN, BOZKURT, ALPER · 2021 to 2024
$1.1M
NICHD NIH HHS R01 HD108473
6 · The paper itself

Abstract

Soft and stretchable strain sensors have found wide applications in health monitoring, motion tracking, and robotic sensing. There is a growing demand for strain sensors in amphibious environments, such as implantable sensors, wearable sensors for swimmers/divers, and underwater robotic sensors. However, developing a sensitive, stretchable, and robust amphibious strain sensor remains challenging. This work presents an encapsulated stretchable amphibious strain sensor. The conductive layer, made of silver nanowires embedded below the surface of polydimethylsiloxane, was sandwiched by two layers of thermoplastic polyurethane. Periodic sharp cuts were introduced to change the direction of flow from across the sensor to along the conductive path defined by the opening cracks. The crack advancing and opening is controlled by a unique combination of weak/strong interfaces within the sandwich structure. The cut design and the interfacial interactions between the layers were investigated. The strain sensor exhibited a high gauge factor up to 289, a linear sensing response, a fast response time (53 ms), excellent robustness against over-strain, and stability after 16 000 loading cycles and 20 days in an aqueous saline solution. The functionality of this amphibious strain sensor was demonstrated by tracking the motion of a robotic fish, undertaking language recognition underwater, and monitoring the blood pressure of a porcine aorta. This illustrates the promising potential for this strain sensor for both underwater use and surgically implantable applications.

Identifiers

PMID39105300
PMCPMC11472868

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.