Evidence map›Paper›PMID 39103449›Full record

ArticleScientific reports2024

Columnar excitation fluorescence microscope for accurate evaluation of quantum properties of color centers in bulk materials.

Yuta Masuyama, Chikara Shinei, Shuya Ishii, Hiroshi Abe, Takashi Taniguchi, Tokuyuki Teraji, Takeshi Ohshima

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yuta MasuyamaNational Institutes for Quantum Science and Technology, Takasaki, Gunma, 370-1292, Japan. masuyama.yuta@qst.go.jp.
Chikara ShineiNational Institute for Materials Science, Tsukuba, Ibaraki, 305-0044, Japan.
Shuya IshiiNational Institutes for Quantum Science and Technology, Takasaki, Gunma, 370-1292, Japan.
Hiroshi AbeNational Institutes for Quantum Science and Technology, Takasaki, Gunma, 370-1292, Japan.
Takashi TaniguchiNational Institute for Materials Science, Tsukuba, Ibaraki, 305-0044, Japan.
Tokuyuki TerajiNational Institute for Materials Science, Tsukuba, Ibaraki, 305-0044, Japan.
Takeshi OhshimaNational Institutes for Quantum Science and Technology, Takasaki, Gunma, 370-1292, Japan.

Funding

Japan Science and Technology Agency JPMJMS2062Japan Society for the Promotion of Science 20H02187Japan Society for the Promotion of Science 20K14392Ministry of Education, Culture, Sports, Science and Technology JPMXS0118067395Ministry of Education, Culture, Sports, Science and Technology JPMXS0118068379Ministry of Internal Affairs and Communications JPMI00316
6 · The paper itself

Abstract

Color centers in wide band-gap semiconductors, which have superior quantum properties even at room temperature and atmospheric pressure, have been actively applied to quantum sensing devices. Characterizing the quantum properties of the color centers in the semiconductor materials and ensuring that these properties are uniform over a wide area are key issues for developing quantum sensing devices based on color centers. In this article, we have developed an optics design protocol optimized for evaluating the quantum properties of color centers and have used this design approach to develop a new microscopy system called columnar excitation fluorescence microscope (CEFM). The essence of this system is to maximize the amount of fluorescence detection of polarized color centers, which is achieved by large-volume and uniform laser excitation along the sample thickness with sufficient laser power density. This laser excitation technique prevents undesirable transitions to undesirable charge states and undesirable light, such as unpolarized color center fluorescence, while significantly increasing the color center fluorescence. This feature enables fast measurements with a high signal-to-noise ratio, making it possible to evaluate the spatial distribution of quantum properties across an entire mm-size sample without using a darkroom, which is difficult with typical confocal microscope systems.

Identifiers

PMID39103449
PMCPMC11300461

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.