Evidence map›Paper›PMID 39103382›Full record

ArticleScientific reports2024

Bacterial reduction and temperature increase of titanium dental implant models treated with a 445 nm diode laser: an in vitro study.

Markus Ahrens, Melanie Spörer, Herbert Deppe, Lucas M Ritschl, Petra Mela

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Markus AhrensChair of Medical Materials and Implants, Department of Mechanical Engineering, TUM School of Engineering and Design, Munich Institute of Biomedical Engineering; Munich Institute of Integrated Materials, Energy and Process Engineering, Technical University of Munich, Munich, Germany.
Melanie SpörerChair of Medical Materials and Implants, Department of Mechanical Engineering, TUM School of Engineering and Design, Munich Institute of Biomedical Engineering; Munich Institute of Integrated Materials, Energy and Process Engineering, Technical University of Munich, Munich, Germany.
Herbert DeppeDepartment of Oral and Maxillofacial Surgery, TUM School of Medicine, Technical University of Munich, Munich, Germany.
Lucas M Ritschl *Chair of Medical Materials and Implants, Department of Mechanical Engineering, TUM School of Engineering and Design, Munich Institute of Biomedical Engineering; Munich Institute of Integrated Materials, Energy and Process Engineering, Technical University of Munich, Munich, Germany.
Petra Mela *Chair of Medical Materials and Implants, Department of Mechanical Engineering, TUM School of Engineering and Design, Munich Institute of Biomedical Engineering; Munich Institute of Integrated Materials, Energy and Process Engineering, Technical University of Munich, Munich, Germany. petra.mela@tum.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this in vitro study, the use of a 445 nm diode laser was investigated for the decontamination of titanium dental implants. Different irradiation protocols and the effect of repetitive laser irradiation on temperature increase and decontamination efficacy were evaluated on titanium implant models. An automated setup was developed to realize a scanning procedure for a full surface irradiation to recapitulate a clinical treatment. Three irradiation parameter sets A (continuous wave, power 0.8 W, duty cycle (DC) 100%, and 5 s), B (pulsed mode, DC 50%, power 1.0 W, and 10 s), and C (pulsed mode, DC 10%, power 3.0 W, and 20 s) were used to treat the rods for up to ten consecutive scans. The resulting temperature increase was measured by a thermal imaging camera and the decontamination efficacy of the procedures was evaluated against Escherichia coli and Staphylococcus aureus, and correlated with the applied laser fluence. An implant's temperature increase of 10 °C was set as the limit accepted in literature to avoid thermal damage to the surrounding tissue in vivo. Repeated irradiation of the specimens resulted in a steady increase in temperature. Parameter sets A and B caused a temperature increase of 11.27 ± 0.81 °C and 9.90 ± 0.37 °C after five consecutive laser scans, respectively, while parameter set C resulted in a temperature increase of only 8.20 ± 0.53 °C after ten surface scans. The microbiological study showed that all irradiation parameter sets achieved a complete bacterial reduction (99.9999% or 6-log

Indexed as

Dental ImplantsEscherichia coliLasers, SemiconductorStaphylococcus aureusTitaniumDecontaminationHumansIn Vitro TechniquesTemperatureDental ImplantsTitanium445 nm diode laserDecontaminationDental implantsDentistryImplant temperaturePeri-implantitis

Identifiers

PMID39103382
PMCPMC11300767

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials