Evidence map›Paper›PMID 39100359›Full record

ArticleACS omega2024

Dual-Target Additively Manufactured Electrochemical Sensor for the Multiplexed Detection of Protein A29 and DNA of Human Monkeypox Virus.

Luiz Ricardo G Silva, Jéssica S Stefano, Cristiane Kalinke, Robert D Crapnell, Laís C Brazaca, Luiz H Marcolino-Junior, Marcio F Bergamini, Craig E Banks, Bruno C Janegitz

Abstract read
In one paragraph

Article in ACS omega, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Luiz Ricardo G SilvaLaboratory of Sensors, Nanomedicine and Nanostructured Materials, Federal University of São Carlos, Araras 13600-970, Brazil.
Jéssica S StefanoLaboratory of Sensors, Nanomedicine and Nanostructured Materials, Federal University of São Carlos, Araras 13600-970, Brazil.ORCID https://orcid.org/0000-0002-2838-3555
Cristiane KalinkeInstitute of Chemistry, University of Campinas (Unicamp), São Paulo 13083-859, Brazil.
Robert D CrapnellFaculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, United Kingdom.
Laís C BrazacaSão Carlos Institute of Chemistry, University of São Paulo, São Carlos, SP 13083-970, Brazil.ORCID https://orcid.org/0000-0002-0456-7552
Luiz H Marcolino-JuniorChemistry Department, Laboratory of Electrochemical Sensors (LabSensE), Federal University of Paraná, Curitiba, PR 81531-980, Brazil.ORCID https://orcid.org/0000-0002-6279-469X
Marcio F BergaminiChemistry Department, Laboratory of Electrochemical Sensors (LabSensE), Federal University of Paraná, Curitiba, PR 81531-980, Brazil.ORCID https://orcid.org/0000-0002-4600-2250
Craig E BanksFaculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, United Kingdom.ORCID https://orcid.org/0000-0002-0756-9764
Bruno C JanegitzLaboratory of Sensors, Nanomedicine and Nanostructured Materials, Federal University of São Carlos, Araras 13600-970, Brazil.ORCID https://orcid.org/0000-0001-9707-9795

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Herein, we present the first 3D-printed electrochemical portable biodevice for the detection of monkeypox virus (MKPV). The electrochemical device consists of two biosensors: an immunosensor and a genosensor specifically designed for the detection of the protein A29 and a target DNA of MKPV, respectively. The electrodes were manufactured using lab-made ultraflexible conductive filaments composed of carbon black, recycled PLA from coffee pods, and castor oil as a plasticizer. The sensors created through 3D printing technology exhibited good reproducibility and repeatability of analytical responses. Furthermore, both the immunosensor and genosensor demonstrated excellent MKPV detection capabilities, with a linear range from 0.01 to 1.0 μmol L

Identifiers

PMID39100359
PMCPMC11292847

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.