Evidence map›Paper›PMID 39099903›Full record

ArticleCureus2024

An Innovative Approach for Management of Unfavorable Bilateral Mandibular Lingual Undercuts With Collapsible Type Complete Denture: A Case Report.

Keerthivasan Srinivasan, Ananya Aparoopa, Lena Priya, Harini Krish, Aarthi S

Abstract readCase Reports
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Keerthivasan SrinivasanDepartment of Prosthodontics, Tagore Dental College and Hospital, Chennai, IND.
Ananya AparoopaDepartment of Dentistry, Dharanidhar Medical College and Hospital, Keonijhar, IND.
Lena PriyaDepartment of Prosthodontics, Nandha Dental College and Hospital, Erode, IND.
Harini KrishDepartment of Prosthodontics, Krishnadevaraya College of Dental Sciences, Bangalore, IND.
Aarthi SDepartment of Prosthodontics, Rathinavel Subramaniam College of Arts and Science (RVS) Dental College and Hospital, Coimbatore, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Advanced and uneven residual ridge resorption in mandibular edentulous arches leads to non-retentive and unstable dentures. The hardness of traditional heat-cured acrylic resin makes extending the denture base into bilateral lingual undercuts challenging. This can cause supporting tissue damage, pain, and ulcerations during denture insertion and removal. Although clinical challenges related to limited mouth opening were addressed by modifying the impression technique, incorporating hinges, swing lock attachments, and stainless-steel posts to form collapsible denture bases, there are no documented case reports with proper follow-up regarding the use of such type dentures in cases of mandibular lingual undercuts. A 68-year-old male patient reported, with the chief complaint of missing teeth in the upper and lower jaws for five years and wanting replacement. The intraoral clinical examination yielded findings of a severely compromised mandibular ridge (ACP Class IV) and a moderately compromised maxillary ridge (ACP Class II). In the maxillary arch, the presence of anterior labial undercut, and bilateral undercuts lateral to tuberosity were evident. The patient reported pain on palpation bilaterally in the tuberosity region. Prolonged mandibular edentulism and uneven bone resorption resulted in unfavorable bilateral lingual undercuts, with class III (M.M. House) border tissue attachment in the labial and buccal aspects of the basal tissue area. After enumerating the treatment options, the patient opted for a removable prosthesis for the maxillary and mandibular arch. Pre-prosthetic surgery was done to eliminate tuberosity undercuts. Since the patient was unwilling to take up pre-prosthetic surgical corrections for the mandibular lingual undercuts, a significant challenge emerged: creating a retentive mandibular complete denture without compromising the peripheral seal and retention. A conventional complete denture was fabricated after blocking the unfavorable undercut and reducing the height of the flange. On the recall appointment, the patient complained of reduced retention and food lodgment in the intaglio surface of the denture and pain due to denture movement on mastication. In this case report, stainless steel hinges have been added to the lingual flange of the mandibular complete denture to make it collapsible. The resultant denture facilitated reduced tissue trauma and discomfort during denture removal and insertion and had satisfactory retention and stability compared to the former denture. These collapsible type dentures can be used as an alternative to flexible dentures, wherein patients can't afford surgeries or flexible dentures.

Indexed as

collapsible denturefoldable type prosthesishinge dentureslingual undercutsstainless steel hinges

Identifiers

PMID39099903
PMCPMC11297619

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.