Evidence map›Paper›PMID 39099699›Full record

ArticleFrontiers in oncology2024

Comprehensive dosimetric commissioning of proton minibeam radiotherapy on a single gantry proton system.

Yuting Lin, Wangyao Li, Aoxiang Wang, Daniel Johnson, Gregory N Gan, Hao Gao

Abstract read
In one paragraph

Article in Frontiers in oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Proton minibeam radiotherapy: a review.Frontiers in oncology · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yuting LinDepartment of Radiation Oncology, University of Kansas Medical Center, Kansas City, KS, United States.
Wangyao LiDepartment of Radiation Oncology, University of Kansas Medical Center, Kansas City, KS, United States.
Aoxiang WangDepartment of Radiation Oncology, University of Kansas Medical Center, Kansas City, KS, United States.
Daniel JohnsonDepartment of Radiation Oncology, University of Kansas Medical Center, Kansas City, KS, United States.
Gregory N GanDepartment of Radiation Oncology, University of Kansas Medical Center, Kansas City, KS, United States.
Hao GaoDepartment of Radiation Oncology, University of Kansas Medical Center, Kansas City, KS, United States.

Funding

Novel Optimization Methods and Treatment Planning System for Clinically-Deliverable Truly-Hybrid Proton-Photon RadiotherapyR37CA250921 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI Hao Gao · 2021 to 2026
$2.2M
Simultaneous dose and dose rate optimization for clinical FLASH proton radiotherapyR01CA261964 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI GAO, HAO · 2022 to 2025
$2.0M
NCI NIH HHS R01 CA261964NCI NIH HHS R37 CA250921
6 · The paper itself

Abstract

Background: Proton minibeam radiation therapy (pMBRT) can deliver spatially fractionated dose distributions with submillimeter resolution. These dose distributions exhibit significant heterogeneity in both depth and lateral directions. Accurate characterization of pMBRT doses requires dosimetry devices with high spatial resolution and a wide dynamic range. Furthermore, the dependency of dosimetric measurements on Linear Energy Transfer (LET), as observed in conventional proton therapy, is also present in pMBRT depth dose measurements. Purpose: This work demonstrates the process of performing comprehensive dosimetric measurements to characterize the pMBRT collimator on a clinical single-gantry proton machine, utilizing commercially available dosimetry devices. Methods: The minibeam collimator is designed to be mounted on the clinical nozzle as a beam-modifying accessory. Three collimators, each with a slit opening of 0.4 mm, are thoroughly evaluated. The center-to-center (c-t-c) distances of the slits for these collimators are 2.8 mm, 3.2 mm, and 4.0 mm, respectively. High spatial resolution dosimetry devices are essential for PMBRT dose characterizations. To meet this requirement, two-dimensional (2D) dose measurement devices, Gafchromic films, are used to measure lateral profiles at various depths. Films are also used for depth dose profile measurements in solid water. Additionally, high-resolution point dose detectors, microDiamond, and Razor diode detectors are employed for lateral profile measurements at various depths. Percent depth dose (PDD) measurements of pMBRT in solid water, with various proton energies, collimators, and air gaps, are performed using Gafchromic films. The film's LET dependency for proton beams is corrected to ensure accurate pMBRT PDD measurements. The Monte Carlo simulation tool TOPAS is utilized to compare and validate all experimental measurements. Results: At depths where LET is not a concern, film dose measurements were consistent with microDiamond and Razor diode point measurements. The point detectors need to be orientated with the thin side aligned to the incoming beam. Comparison of the lateral dose profiles extracted from TOPAS simulations, films, microDiamond, and Razor diode detectors shows a passing rate exceeding 98% in 1D gamma analysis at 3% 0.1 mm criteria.However, when the microDiamond detector is orientated to face the pMBRT beam, its spatial resolution may not be sufficient to capture the peak and valley dose accurately. Nevertheless, an accuracy within 2% can still be achieved when comparing the average dose. The PDD measurements show that the peak valley dose ratio (PVDR) of pMBRT can be altered at different depths with different air gaps using the same collimator or different collimators of different c-t-c distances. Conclusion: Our study demonstrates that comprehensive dose measurements for pMBRT can be conducted using standard clinical dose measurement devices. These measurements are indispensable for guiding and ensuring accurate dose reporting in pre-clinical studies using the pMBRT technique.

Indexed as

film dosimetryproton dosimetryproton mini-beamproton therapysmall field dosimetryspatially fractionated radiotherapy

Identifiers

PMID39099699
PMCPMC11294745

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked