ArticleScientific reports2024
Optimization of UWB indoor positioning based on hardware accelerated Fuzzy ISODATA.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Optimization of UWB Base Station Deployment for Formwork Scaffolds in Underground Construction with Sub-Meter Positioning Accuracy by Semi-Controlled Field Experiments.Sensors (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
With the development of wireless communication technology, Ultra-Wideband (UWB) has become an important solution for indoor positioning. In complex indoor environments, the influence of non-line-of-sight (NLOS) factors leads to increased positioning errors. To improve the positioning accuracy, fuzzy iterative self-organizing data analysis clustering algorithm (ISODATA) is introduced to process a large amount of UWB data to reduce the influence of NLOS factors, and to stabilize positioning error within 2 cm, enhances the accuracy of the positioning system. To further improve the running efficiency of the algorithm, FPGA is used to accelerate the key computational part of the algorithm, compared with running on the MATLAB platform, which improves the speed about 100 times, enhances the algorithm's computational speed dramatically.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.