Evidence map›Paper›PMID 39093491›Full record

ArticleWorld journal of urology2024

Real-world experience with the new pulsed solid-state Thulium: YAG laser (Thulio) for endoscopic enucleation of the prostate.

Maximilian Ferry von Bargen, M Glienke, S Tonyali, A Sigle, K Wilhelm, M Schoenthaler, C Gratzke, A Miernik

Abstract read
In one paragraph

Article in World journal of urology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Maximilian Ferry von BargenDepartment of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Hugstetter Str. 55, 79106, Freiburg, Germany. maximilian.vonbargen@uniklinik-freiburg.de.
M GlienkeDepartment of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Hugstetter Str. 55, 79106, Freiburg, Germany.
S TonyaliDepartment of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Hugstetter Str. 55, 79106, Freiburg, Germany.
A SigleDepartment of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Hugstetter Str. 55, 79106, Freiburg, Germany.
K WilhelmDepartment of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Hugstetter Str. 55, 79106, Freiburg, Germany.
M SchoenthalerDepartment of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Hugstetter Str. 55, 79106, Freiburg, Germany.
C GratzkeDepartment of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Hugstetter Str. 55, 79106, Freiburg, Germany.
A MiernikDepartment of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Hugstetter Str. 55, 79106, Freiburg, Germany.ORCID http://orcid.org/0000-0001-5894-9647

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe solid-state Thulium laser (Tm: YAG) is a novel alternative to the widely used Holmium laser for endoscopic enucleation of the prostate (EEP) due to its relatively high peak power. The aim of this study was to examine the efficacy and safety of a new pulsed Tm: YAG laser in its first application in humans.

methodsData were retrospectively collected for the first 103 patients who underwent EEP with a new pulsed solid-state Tm: YAG laser (Thulio

resultsThe mean preoperative prostate volume was 105.6 ± 55.0 ml. Median enucleation speed was 4.1 g per minute (range 1.1-9.7). Short-term postoperative complications occurred in 21 patients (20.4%), but no high-grade complications (CDC ≥ IV) were observed. Five patients suffered gross haematuria and required reintervention (CDC IIIb; 4.9%). After 15 months, 76 patients (73.8%) participated in the follow-up interview, where seven patients (9.2%) reported complications, including two reinterventions for urethral strictures (CDC IIIb; 2.6%). Most patients reported an improvement in continence (54.0%) and urine stream (93.4%), but no difference in erectile function (81.6%). No persistent dysuria was reported. Patient satisfaction with the surgery results was very high (96.1%).

conclusionEndoscopic enucleation of the prostate with the new pulsed solid-state Tm: YAG laser is a safe and effective option for surgical BPH treatment.

trial registrationGerman Clinical Trials Register number: DRKS00031676. Registration date: 10 May 2023, retrospectively registered.

Indexed as

Lasers, Solid-StateProstatic HyperplasiaThuliumAgedAged, 80 and overEndoscopyHumansLaser TherapyMaleMiddle AgedPostoperative ComplicationsProstatectomyRetrospective StudiesTreatment OutcomeThuliumBenign prostate hyperplasia (BPH)Endoscopic enucleation of the prostate (EEP)Holmium laser enucleation of the prostate (HoLEP)Thulium laser enucleation of the prostate (ThuLEP)

Identifiers

PMID39093491
PMCPMC11296962

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.