Evidence map›Paper›PMID 39093098›Full record

ArticleTechnology and health care : official journal of the European Society for Engineering and Medicine2024

A biomechanical study of a polymer material bundled rib fracture fixator.

Yongmin Zhang, Dongbin Wang, Hao Gong, Haosen Tang, Guangqi Dong, Bin Wang, Honggang Xia

Abstract read
In one paragraph

Article in Technology and health care : official journal of the European Society for Engineering and Medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yongmin ZhangDepartment of Cardiothoracic Surgery, Tianjin Hospital Affiliated to Tianjin University, Tianjin, China.
Dongbin WangDepartment of Cardiothoracic Surgery, Tianjin Hospital Affiliated to Tianjin University, Tianjin, China.
Hao GongDepartment of Cardiothoracic Surgery, Tianjin Hospital Affiliated to Tianjin University, Tianjin, China.
Haosen TangGraduate School, Tianjin Medical University, Tianjin, China.
Guangqi DongGraduate School, Tianjin Medical University, Tianjin, China.
Bin WangSchool of Materials, Tianjin University, Tianjin, China.
Honggang XiaDepartment of Cardiothoracic Surgery, Tianjin Hospital Affiliated to Tianjin University, Tianjin, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRib fractures are one of the most common blunt injuries, accounting for approximately 10% of all trauma patients and 60% of thoracic injuries. Multiple rib fractures, especially flail chest, can cause local chest wall softening due to the loss of rib support, leading to paradoxical breathing, severe pain, and a high likelihood of accompanying lung contusions.

objectiveThis study investigates the mechanical properties of a new polymer material rib internal fixator to provide theoretical data for its clinical use.

methodsWe conducted in vitro mechanical tests on 20 fresh caudal fin sheep ribs, using different fracture models across four randomly assigned groups (five ribs per group). The fixators were assessed using non-destructive three-point bending, torsion, and unilateral compression tests, with results averaged. Additionally, finite element analysis compared stress and strain in the polymer fixators and titanium alloy rib plates during bending and torsion tests.

resultsIn vitro tests showed that the polymer fixators handled loads effectively up to a maximum without increase beyond a certain displacement. Bending and torsion tests via finite element analysis showed the polymer material sustained lower maximum equivalent stresses (84.455 MPa and 14.426 MPa) compared to titanium alloy plates (219.88 MPa and 46.47 MPa).

conclusionThe polymer rib fixator demonstrated sufficient strength for rib fracture fixation and was superior in stress management compared to titanium alloy plates in both bending and torsion tests, supporting its potential clinical application.

Indexed as

Finite Element AnalysisPolymersRib FracturesAnimalsBiomechanical PhenomenaFracture Fixation, InternalInternal FixatorsMaterials TestingSheepStress, MechanicalTitaniumPolymersTitaniumbiomechanicsfinite element analysisinternal fixationRib fracturerib internal fixator

Identifiers

PMID39093098
PMCPMC11612998

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.