Evidence map›Paper›PMID 39092336›Full record

ArticleCureus2024

The Role of CT Perfusion in Differentiating Benign Versus Malignant Focal Pulmonary Lesions.

Kriti Kundu, Aman Kumar, Rajesh Malik, Radha Sarawagi, Alkesh Khurana, Jitendra Sharma, Abhinav C Bhagat, Ankur Patel

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Kriti KunduRadiology, All India Institute of Medical Sciences, Bhopal, Bhopal, IND.
Aman KumarRadiology, All India Institute of Medical Sciences, Bhopal, Bhopal, IND.
Rajesh MalikRadiology, All India Institute of Medical Sciences, Bhopal, Bhopal, IND.
Radha SarawagiRadiology, All India Institute of Medical Sciences, Bhopal, Bhopal, IND.
Alkesh KhuranaPulmonary and Critical Care Medicine, All India Institute of Medical Sciences, Bhopal, Bhopal, IND.
Jitendra SharmaRadiology, All India Institute of Medical Sciences, Bhopal, Bhopal, IND.
Abhinav C BhagatRadiology, All India Institute of Medical Sciences, Bhopal, Bhopal, IND.
Ankur PatelRadiology, All India Institute of Medical Sciences, Bhopal, Bhopal, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundContrast-enhanced CT scan is the standard imaging for the characterization and evaluation of focal parenchymal lung lesions. It relies on morphology and enhancement patterns for the characterization of lung lesions. However, there is significant overlap among imaging features of various malignant and benign lesions. Hence, it is often necessary to obtain tissue diagnosis with invasive percutaneous or endoscopic-guided tissue sampling. It is often desirable to have non-invasive techniques that can differentiate malignant and benign lung lesions. CT perfusion is an emerging CT technology that allows functional assessment of tissue vascularity through various parameters and can help in differentiating benign and malignant focal lung lesions.

objectiveThe purpose of this study was to assess the role of the CT perfusion technique in differentiating malignant and benign focal parenchymal lung lesions. MATERIALS AND

methodsIn this prospective observational study, CT perfusion was performed on 41 patients with focal parenchymal lung lesions from December 2020 to June 2022. The four-dimensional range was planned to cover the entire craniocaudal extent of the lesion, followed by a volume perfusion CT (VPCT) of the lesion. A total of 27 dynamic datasets were acquired with a scan interval of 1.5 seconds and a total scan time of 42 seconds. CT perfusion parameters of blood flow (BF), blood volume (BV), and k-trans of the lesion were measured with mathematical algorithms available in the Syngo.via CT perfusion software (Siemens Healthcare, Erlangen, Germany).

resultsThe median BV in benign lesions was found to be 5.5 mL/100 g, with an interquartile range of 3.3-6.9 and a p-value < 0.001. The median BV in malignant lesions was found to be 11.35 mL/100 g, with an interquartile range of 9.57-13.21 and a p-value ≤ 0.001. The median BF for benign lesions was 45.5 mL/100 g/min, with an interquartile range of 33.8-48.5 and a p-value ≤ 0.001. The median BF for malignant lesion was 61.77 mL/100 g/min, with an interquartile range of 33.8-48.5 and a p-value ≤ 0.001. The median k-trans in the case of benign lesions was found to be 4.2 mL/100 g/min, with an interquartile range of 3.13-6.8 and a p-value ≤ 0.001. The median k-trans in the case of the malignant lesion was found to be 12.05 mL/100g/min, with an interquartile range of 7.20-33.42 and a p-value < 0.001. Our study has also shown BV to have an accuracy of 92.68%, sensitivity of 93.3%, and specificity of 90.01%.

conclusionOur study has shown that CT perfusion values of BV, BF, and k-trans can be used to differentiate between benign and malignant focal lung parenchymal lesions. K-trans is the most sensitive parameter while BV and BF have greater accuracy and specificity.

Indexed as

benign lung lesionsct perfusiondifferentiate malignant and benign lung lesionsfocal lung lesionslung cancermalignantpulmonary nodule characterization

Identifiers

PMID39092336
PMCPMC11290953

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.