Evidence map›Paper›PMID 39092300›Full record

ArticleClinics in orthopedic surgery2024

Load-Dependent Characteristics of Cruciate-Retaining and Posterior-Stabilized Total Knee Arthroplasty: A Biomechanical Study.

Jason H Lee, Ran Schwarzkopf, Genevieve Fraipont, Ghita Bouzarif, Michelle H McGarry, Thay Q Lee

Abstract read
In one paragraph

Article in Clinics in orthopedic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jason H LeeSouthern California Permanente Medical Group, Department of Orthopaedics, Fontana Medical Center, Los Angeles, CA, USA.ORCID https://orcid.org/0000-0001-6838-9575
Ran SchwarzkopfNew York University Langone Orthopedic Hospital, New York, NY, USA.ORCID https://orcid.org/0000-0003-0681-7014
Genevieve FraipontOrthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA.ORCID https://orcid.org/0009-0004-5664-2720
Ghita BouzarifDepartment of Internal Medicine, Highland Hospital, Oakland, CA, USA.ORCID https://orcid.org/0009-0005-0634-3228
Michelle H McGarryOrthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA.ORCID https://orcid.org/0000-0003-2266-2622
Thay Q LeeOrthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA.ORCID https://orcid.org/0000-0002-1639-0280

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Increased load bearing across the patellofemoral and tibiofemoral articulations has been associated with total knee arthroplasty (TKA) complications. Therefore, the purpose of this study was to quantify the biomechanical characteristics of the patellofemoral and tibiofemoral joints and simulate varying weight-bearing demands after posterior cruciate ligament-retaining (CR) and posterior-stabilized (PS) TKAs. Methods: Eight fresh-frozen cadaveric knees (average age, 68.4 years; range, 40-86 years) were tested using a custom knee system with muscle-loading capabilities. The TKA knees were tested with a CR and then a PS TKA implant and were loaded at 6 different flexion angles from 15° to 90° with progressively increasing loads. The independent variables were the implant types (CR and PS TKA), progressively increased loading, and knee flexion angle (KFA). The dependent variables were the patellofemoral and tibiofemoral kinematics and contact characteristics. Results: The results showed that at higher KFAs, the position of the femur translated significantly more posterior in CR implants than in PS implants (36.6 ± 5.2 mm and 32.5 ± 5.7 mm, respectively). The patellofemoral contact force and contact area were significantly greater in PS than in CR implants at higher KFAs and loads (102.4 ± 12.5 N and 88.1 ± 10.9 N, respectively). Lastly, the tibiofemoral contact force was significantly greater in the CR than the PS implant at flexion angles of 45°, 60°, 75°, and 90° KFA, the average at these flexion angles for all loads tested being 246.1 ± 42.1 N and 192.8 ± 54.8 N for CR and PS implants, respectively. Conclusions: In this biomechanical study, CR TKAs showed less patellofemoral contact force, but more tibiofemoral contact force than PS TKAs. For higher loads across the joint and at increased flexion angles, there was significantly more posterior femur translation in the CR design with a preserved posterior cruciate ligament and therefore significantly less patellofemoral contact area and force than in the PS design. The different effects of loading on implants are an important consideration for physicians as patients with higher load demands should consider the significantly greater patellofemoral contact force and area of the PS over the CR design.

Indexed as

Arthroplasty, Replacement, KneePosterior Cruciate LigamentWeight-BearingAdultAgedAged, 80 and overBiomechanical PhenomenaCadaverFemaleHumansKnee JointKnee ProsthesisMaleMiddle AgedPatellofemoral JointRange of Motion, ArticularContact areaContact forceCruciate retainingPosterior stabilizedTotal knee arthroplasty

Identifiers

PMID39092300
PMCPMC11262949

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.