Evidence map›Paper›PMID 39091280›Full record

ArticleOptical engineering (Redondo Beach, Calif.)2024

Acousto-optic-based time domain electric field sensor for magnetic resonance imaging applications.

Yusuf S Yaras, Lee W Bradley, D Korel Yildirim, Robert J Lederman, Ozgur Kocaturk, John Oshinski, F Levent Degertekin

Abstract read
In one paragraph

Article in Optical engineering (Redondo Beach, Calif.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yusuf S YarasGeorgia Institute of Technology, G.W. Woodruff School of Mechanical Engineering, Atlanta, Georgia, United States.ORCID 0000-0002-1117-559X
Lee W BradleyGeorgia Institute of Technology, G.W. Woodruff School of Mechanical Engineering, Atlanta, Georgia, United States.
D Korel YildirimNational Institutes of Health, National Heart Lung and Blood Institute, Bethesda, Maryland, United States.
Robert J LedermanNational Institutes of Health, National Heart Lung and Blood Institute, Bethesda, Maryland, United States.ORCID 0000-0003-1202-6673
Ozgur KocaturkBogazici University, Institute of Biomedical Engineering, Istanbul, Turkey.ORCID 0000-0002-2230-5230
John OshinskiGeorgia Institute of Technology, Wallace H. Coulter Department of Biomedical Engineering, Atlanta, Georgia, United States.
F Levent DegertekinGeorgia Institute of Technology, G.W. Woodruff School of Mechanical Engineering, Atlanta, Georgia, United States.ORCID 0000-0001-9198-8525

Funding

Novel catheter treatment of valve diseaseZIAHL006040 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI LEDERMAN, ROBERT J · 2010 to 2025
$23.6M
MRI catheter design and fabricationZIAHL006041 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI LEDERMAN, ROBERT J · 2014 to 2025
$12.2M
Acousto-optical RF field sensors for safer diagnostic and interventional MRIR01EB029331 · NIBIB · GEORGIA INSTITUTE OF TECHNOLOGY · PI DEGERTEKIN, F. LEVENT, KOCATURK, OZGUR · 2020 to 2023
$1.6M
Intramural NIH HHS ZIA HL006041NIBIB NIH HHS R01 EB029331
6 · The paper itself

Abstract

An acousto-optic (AO)-based electric field sensor is presented for time domain measurement under magnetic resonance imaging (MRI). A fully MR-compatible sensor is designed and fabricated using a phase-shifted fiber Bragg grating mechanically coupled to a piezoelectric transducer. Mechanical resonance of the piezoelectric transducer is matched to the operating frequencies of commonly used MRI systems to increase the sensitivity of the sensor. Sensitivity of the sensor is measured as 1.27 mV/V/m, with a minimum detectable electric field of 4.4 mV/m/√/Hz. Directivity of the sensor is measured with a 18 dB orthogonal component rejection. The dynamic range of the sensor is calculated as 117 dB/Hz, which allows the measurement of electric fields up to 3.2 kV/m. In MRI studies, the AO sensor was able detect local hot spots around a reference implant accurately with high signal-to-noise ratio. AO sensor exhibited similar or better performance when compared with commercially available MRI compatible electric field sensors. Furthermore, the small size of the sensor with the flexible fiber optic link could allow

Indexed as

acousto-opticelectric field sensorfiber Bragg gratingfiber optic sensormagnetic resonance imagingradio frequency safety

Identifiers

PMID39091280
PMCPMC11293619

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.