ArticleOptical engineering (Redondo Beach, Calif.)2024
Acousto-optic-based time domain electric field sensor for magnetic resonance imaging applications.
Article in Optical engineering (Redondo Beach, Calif.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Antenna-Driven Optical Fiber-Based Acousto-Optic Modulation Devices: Electro-Mechanical Model and Experimental Validation.Sensors and actuators. A, Physical · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
An acousto-optic (AO)-based electric field sensor is presented for time domain measurement under magnetic resonance imaging (MRI). A fully MR-compatible sensor is designed and fabricated using a phase-shifted fiber Bragg grating mechanically coupled to a piezoelectric transducer. Mechanical resonance of the piezoelectric transducer is matched to the operating frequencies of commonly used MRI systems to increase the sensitivity of the sensor. Sensitivity of the sensor is measured as 1.27 mV/V/m, with a minimum detectable electric field of 4.4 mV/m/√/Hz. Directivity of the sensor is measured with a 18 dB orthogonal component rejection. The dynamic range of the sensor is calculated as 117 dB/Hz, which allows the measurement of electric fields up to 3.2 kV/m. In MRI studies, the AO sensor was able detect local hot spots around a reference implant accurately with high signal-to-noise ratio. AO sensor exhibited similar or better performance when compared with commercially available MRI compatible electric field sensors. Furthermore, the small size of the sensor with the flexible fiber optic link could allow
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.