Evidence map›Paper›PMID 39090634›Full record

ArticleBMC oral health2024

Post sterilization of intraoral scan body and the effect it has on the axes and distances between three adjacent implants: in-vitro study.

Gil Ben-Izhack, Diva Lugassy, Ofir Rosner, Joseph Nissan, Shir Rachmiel, Yara Khoury, Asaf Shely

Abstract read
In one paragraph

Article in BMC oral health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Gil Ben-IzhackDepartment of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, 6997801, Israel. gil.ben.izhack@gmail.com.
Diva LugassyDepartment of Orthodontics, The Maurice and Gabriela Goldschleger School of Dental Medicine, Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, 6997801, Israel.
Ofir RosnerDepartment of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, 6997801, Israel.
Joseph NissanDepartment of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, 6997801, Israel.
Shir RachmielDepartment of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, 6997801, Israel.
Yara KhouryDepartment of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, 6997801, Israel.
Asaf ShelyDepartment of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, 6997801, Israel.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe purpose of this pilot in-vitro study was to assess the effect of sterilization on the intra-implant axis, inter-implant axis, intra-implant distance and inter-implant distance of three implants in a straight line by using laboratory scanner (LBS) versus intra-oral scanner (IOS) with intra-oral scan bodies (ISB).

methodsA printed 3D model with three internal hex analogs in the positions 15#,16#,17# was used. Zirkonzhan (ZZ) intra-oral scan body (ISB), two-piece titanium was used. The ZZ ISBs were scanned by 7 Series dental wings (LBS) and 30 times by Primescan (IOS) pre sterilization and 30 times post sterilization. For each scan (pre and post) stereolithography (STL) file was created and a comparison between all the scans pre sterilization and post sterilization were superimposed on the laboratory scan by using a 3D analyzing software. A Kolmogorov-Smirnov test performed followed by Wilcoxon Signed Ranks tests. (p < 0.05) Results: Post sterilization of the ZZ ISB, the mean errors were significantly increased for the inter-implant distances (p < 0.0005), intra-implant distances 1,2,3 (p < 0.0005), intra-implant axis 1,3 (p < 0.0005) and inter-implant axes 13,23 (p < 0.05). In contrast, the mean errors for intra-implant axis 2 (p < 0.0005) and inter-implant axis 12 (p < 0.0005) were significantly reduced.

conclusionsZZ ISB showed changes in all four parameters after sterilization. The middle ISB had the largest changes in mean error regarding all four parameters. Sterilization process may affect the three-dimensional (3D) structure of the ZZ ISB after three cycles. There is a lack in the literature in this field and there is a need for further studies to explore the effect of sterilization (multiple cycles) on different ISBs and for creating an approved guidelines regarding the amount of sterilization for each ISB in the industry.

Indexed as

Dental ImplantsSterilizationDental Prosthesis DesignHumansImaging, Three-DimensionalIn Vitro TechniquesModels, DentalPilot ProjectsPrinting, Three-DimensionalStereolithographyDental ImplantsAutoclaveCAD-CAMDental implantsImplant axisIntraoral scan bodyOral rehabilitationPrimescanScan abutmentSterilizationTitanium

Identifiers

PMID39090634
PMCPMC11295592

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.