Evidence map›Paper›PMID 39085439›Full record

ArticleArchives of orthopaedic and trauma surgery2024

The temperature profile in elbow arthroscopy using radiofrequency ablation.

Felix Krane, Kilian Wegmann, Stephanie Kahmann, Andreas Harbrecht, Lars Peter, Tim Leschinger

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Felix KraneFaculty of Medicine and University Hospital, Center for Orthopedic, Trauma and Plastic Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany. felix.krane1@uk-koeln.de.ORCID http://orcid.org/0009-0000-6001-5747
Kilian WegmannOrthopädische Chirurgie München GbR, Steinerstr. 6, 81369, Munich, Germany.
Stephanie KahmannFaculty of Medicine and University Hospital, Center for Orthopedic, Trauma and Plastic Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
Andreas HarbrechtFaculty of Medicine and University Hospital, Center for Orthopedic, Trauma and Plastic Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
Lars PeterFaculty of Medicine and University Hospital, Center for Orthopedic, Trauma and Plastic Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
Tim LeschingerFaculty of Medicine and University Hospital, Center for Orthopedic, Trauma and Plastic Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionOver the last decades, arthroscopic surgery has become increasingly relevant as its minimally invasive approach offers many benefits. To investigate the risks of orthoscopic surgery at the elbow, this study aimed to investigate the development of temperatures in elbow joints while performing radiofrequency ablation in arthroscopic surgery. MATERIALS AND

methodsWe performed standard arthroscopic surgeries with posterolateral, transtricipital and anterolateral approaches on seven cadaveric elbows and performed ablation on predefined locations with or without irrigation. Two temperature probes were positioned into the olecranon fossa and between the ulnar nerve and the medial joint capsule. The temperature data were recorded using a real-time data logger. A bipolar radiofrequency ablation (bRFA) device was used at the medial and lateral recess and in the fossa olecrani over a defined period. Data was then analyzed using Matlab.

resultsUsing bRFA without irrigation results in rapidly increasing temperature within the joint. A significant temperature increase was found within only 5 s without irrigation (p = 0.0052) in the fossa olecrani. We did not observe critical temperatures above 41 °C close to the ulnar nerve within 30 s under constant irrigation (p = 0.0747).

conclusionsRadiofrequency ablation (RFA) can be safely used in elbow arthroscopy with irrigation. The continuous use without irrigation should be limited to 3 s. Despite the anatomical proximity of the ulnar nerve and capsule, we were able to show that a possible rise in temperature most likely does not affect the ulnar nerve.

Indexed as

ArthroscopyElbow JointRadiofrequency AblationCadaverCatheter AblationHumansTherapeutic IrrigationCadaver studyElbow arthroscopyTemperature arthroscopyUlnar nerve

Identifiers

PMID39085439

What OpenQuestion holds