Evidence map›Paper›PMID 39083162›Full record

ArticlePhysical and engineering sciences in medicine2024

Evaluation of direct point dose estimation based on the distribution of the size-specific dose estimate.

Choirul Anam, Heri Sutanto, Riska Amilia, Rini Marini, Sinta Nur Barokah, Noor Diyana Osman, Geoff Dougherty

Abstract readEvaluation Study
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Choirul AnamDepartment of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Central Java, Jl. Prof Soedarto, SH Tembalang, Tembalang, Semarang, 50275, Indonesia. anam@fisika.fsm.undip.ac.id.ORCID http://orcid.org/0000-0003-0156-6797
Heri SutantoDepartment of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Central Java, Jl. Prof Soedarto, SH Tembalang, Tembalang, Semarang, 50275, Indonesia.
Riska AmiliaDepartment of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Central Java, Jl. Prof Soedarto, SH Tembalang, Tembalang, Semarang, 50275, Indonesia.
Rini MariniRegional Public Hospital of Karawang, Jl. Galuh Mas Raya No.1, Sukaharja, Telukjambe Timur, Kabupaten Karawang 41361, West Java, Indonesia.
Sinta Nur BarokahLaboratorium Kalibrasi Alat Ukur Radiasi, Natial Research and Innovation Agency, Jakarta, Indonesia.
Noor Diyana OsmanAdvanced Medical and Dental Institute, Universiti Sains Malaysia, 13200 Kepala Batas, Penang, Malaysia.
Geoff DoughertyDepartment of Applied Physics and Medical Imaging, California State University Channel Islands, Camarillo, CA, 93012, USA.

Funding

Universitas Diponegoro 569-187/UN7.D2/PP/IV/2024
6 · The paper itself

Abstract

The aim of this study was to evaluate the point doses using a distribution of the size-specific dose estimate (SSDE) from axial CT images of in-house phantoms having diameters from 8 to 40 cm. In-house phantoms made of polyester-resin (PESR) mixed with methyl ethyl ketone peroxide (MEKP) were used. The phantoms were built with different diameter sizes of 8, 16, 24, 32, and 40 cm. The phantoms were scanned by Siemens a SOMATOM Perspective-128 slice CT scanner with constant input parameters. The point doses were interpolated from the central SSDE (SSDEc) and the peripheral SSDE (SSDEp). The SSDEc and SSDEp were calculated from the SSDE with h- and k-factors. The point doses were compared to the direct measurements using the nanoDot™ optically-stimulated luminescence dosimeter (OSLD) in dedicated holes on the phantoms. It was found that the point dose decreases as the phantom diameter increased. The doses obtained using two approaches differed by 11% on average. The highest difference was 40% and the lowest difference was < 1%. It was found that dose based on the SSDE concept tended to be higher compared to the measured dose by OSLD. Point dose estimation using the concept of SSDE distribution can be considered an alternative for accurate and simple estimation. This approach still requires improvements to increase its accuracy and its application to estimate the organ dose needs further investigation.

Indexed as

Phantoms, ImagingRadiation DosageDose-Response Relationship, RadiationHumansRadiometryTomography, X-Ray ComputedOSL dosimeterPoint doseSize-specific dose estimatesWater-equivalent diameter

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.